BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T221630
CREATED:20211205T111916Z
LAST-MODIFIED:20260729T093323Z
UID:599-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043E_05_AG
DESCRIPTION:Temperature calibrator calibration \nEPTIS ID: 703492\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: temperature calibrator\nModel / type: Beamex MC5\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type S\n0.11 – 0.0022 % rdg °C with 0° C RJ\n0.17 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Simulation use with Thermocouple Type S\n0.032 °C + 0.0012 % rdg with 0° C RJ\n0.14 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type T\n0.029 °C – 0.0033 % rdg with 0° C RJ\n0.13 °C – 0.0083 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Simulation use with Thermocouple Type T\n0.015 °C with 0° C RJ\n0.13 °C – 0.0067 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with RTD\n0.0020 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\nTemperature Simulation use with RTD\n0.0019 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_05_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Beamex-MC5.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T221630
CREATED:20211208T095445Z
LAST-MODIFIED:20260902T095331Z
UID:654-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_02_AG
DESCRIPTION:IPRT Calibration \nEPTIS ID: 708010\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires IPRT\nModel / type: Klasmeier eXacal Pt100 IH\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.085 °C\n\n\n-80 °C\n0.017 °C\n\n\n-60 °C\n0.017 °C\n\n\n-40 °C\n0.017 °C\n\n\n-20 °C\n0.017 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.031 °C\n\n\n100 °C\n0.028 °C\n\n\n150 °C\n0.028 °C\n\n\n200 °C\n0.028 °C\n\n\n250 °C\n0.028 °C\n\n\n300 °C\n0.028 °C\n\n\n400 °C\n0.072 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-708010/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_02_AG-e1788342730139.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T221630
CREATED:20211208T152820Z
LAST-MODIFIED:20260902T094552Z
UID:659-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_03_PT_AG
DESCRIPTION:IPRT with a Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: IPRT with a Digital Readout Thermometer calibration\nModel: Fluke 1502A + Fluke 5609\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.086 °C\n\n\n-80 °C\n0.019 °C\n\n\n-60 °C\n0.019 °C\n\n\n-40 °C\n0.019 °C\n\n\n-20 °C\n0.019 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.019 °C\n\n\n100 °C\n0.029 °C\n\n\n150 °C\n0.029 °C\n\n\n200 °C\n0.029 °C\n\n\n250 °C\n0.029 °C\n\n\n300 °C\n0.029 °C\n\n\n400 °C\n0.073 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/1502A-SPRT-scaled-e1788342253645.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20260920T221630
CREATED:20211129T143141Z
LAST-MODIFIED:20260902T093706Z
UID:543-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_01_T_AG
DESCRIPTION:T type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.14 °C\n\n\n-80 °C\n0.14 °C\n\n\n-60 °C\n0.14 °C\n\n\n-40 °C\n0.14 °C\n\n\n-20 °C\n0.14 °C\n\n\n0 °C\n0.069 °C\n\n\n50 °C\n0.069 °C\n\n\n100 °C\n0.14 °C\n\n\n150 °C\n0.14 °C\n\n\n200 °C\n0.14 °C\n\n\n250 °C\n0.14 °C\n\n\n300 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797772/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/17043T_01_T_AG-e1788341313143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20260920T221630
CREATED:20211207T102108Z
LAST-MODIFIED:20260902T100907Z
UID:633-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_03_T_AG
DESCRIPTION:T type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: digital readout with thermocouple\nModel / type: digital readout Beamex MC2-TE + T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.16 °C\n\n\n-80 °C\n0.16 °C\n\n\n-60 °C\n0.16 °C\n\n\n-40 °C\n0.16 °C\n\n\n-20 °C\n0.16 °C\n\n\n0 °C\n0.075 °C\n\n\n50 °C\n0.075 °C\n\n\n100 °C\n0.17 °C\n\n\n150 °C\n0.17 °C\n\n\n200 °C\n0.17 °C\n\n\n250 °C\n 0.17 °C\n\n\n300 °C\n 0.17 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_t-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_03_T_AG-e1788341141821.jpg
END:VEVENT
END:VCALENDAR