BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20231228T160035Z
LAST-MODIFIED:20261119T105055Z
UID:2126-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043T_03_PT_EX
DESCRIPTION:SPRT with Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / Item: SPRT with a Digital Readout Thermometer calibration\nModel / type: Fluke 1522 + Fluke 5609-400-G\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.004 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_03_pt_ex-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/catena-e1703780406498.jpeg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T083030Z
LAST-MODIFIED:20261009T093036Z
UID:2586-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_-25_25kR_AG
DESCRIPTION:Pneumatic pressure transducer from -25 kPa to 25 kPa calibration\, gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0004\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-25\, -20\, -15\, -10\, 0\, 5\, 10\, 15\, 20\, 25) kPa \nReference Laboratory CMC:\n|0.0019 %| rdg + 0.12 Pa (range -25 kPa to 0 kPa)\n0.0019 % rdg + 0.06 Pa (range 0 kPa to 25 kPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_25kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0004.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T084057Z
LAST-MODIFIED:20261009T094717Z
UID:2589-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_170kA_AG
DESCRIPTION:Pneumatic pressure transducer from 1.4 kPa to 170 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: Paroscientific 745\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(1.4\, 17.0\, 34.0\, 51.0\, 68.0\, 85.0\, 102.0\, 119.0\, 136.0\, 153.0\, 170.0) kPa \nReference Laboratory CMC:\n0.0019 % rdg + 0.29 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_170ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T092403Z
LAST-MODIFIED:20261009T094406Z
UID:2597-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_350kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 350 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DHI RPM1-G0100-R\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 35\, 70\, 105\, 140\, 175\, 210\, 245\, 280\, 315\, 350) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_350kr_ag/
CATEGORIES:ILC - Pressure
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T092926Z
LAST-MODIFIED:20261009T093338Z
UID:2601-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 700 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0100\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0100.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T093904Z
LAST-MODIFIED:20261009T095023Z
UID:2603-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kA_AG
DESCRIPTION:Pneumatic pressure transducer from 12 kPa to 700 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: ‘Paroscientific Digiquartz 715 + Paroscientific Digiquartz 6000-100A\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(12\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0017 % rdg + 0.31 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-715-6000-100A.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T094759Z
LAST-MODIFIED:20261009T093433Z
UID:2606-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 3.5 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: CalRef Cube-P\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.40 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Cube-P.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T095222Z
LAST-MODIFIED:20261009T095157Z
UID:2608-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.17 MPa to 3.5 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 A0500\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.17\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-A0500.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T095819Z
LAST-MODIFIED:20261009T095255Z
UID:2611-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_7MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.2 MPa to 7 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.2\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T152046
CREATED:20241102T100749Z
LAST-MODIFIED:20261119T115234Z
UID:2617-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_20MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 20 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific 745-3K\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 2\, 4\, 6\, 8\, 10\, 12\, 14\, 16\, 18\, 20) MPa \nReference Laboratory CMC: \n0.005 5 % rdg + 1.8 kPa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_20mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT