BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:AG Metrology
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20270101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20261122T151017
CREATED:20260118T082742Z
LAST-MODIFIED:20261119T115224Z
UID:3807-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043E_01_03_HVP_EX
DESCRIPTION:High voltage meter with probe calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: high voltage meter + probe\nModel: Vitrek 4700 + Vitrek HVL-70\nExternal provider for the calibration of the PT item:  an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nDCV RANGE\n\n\n\n\n1600.00 V\n0.01 % rdg\n1000.00 V\n\n\n16000.0 V\n0.01 % rdg\n(-10000.0\, 10000.0) V\n\n\n70000 V\n0.01 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\nACV RANGE 50 Hz\n\n\n\n\n1600.00 V\n0.05 % rdg\n1000.00 V\n\n\n 16000.0 V\n0.05 % rdg\n10000.0 V\n\n\n70000 V\n0.05 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: even-numbered years in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_hvp_ex/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20211209T162423Z
LAST-MODIFIED:20261009T103506Z
UID:671-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_01_EX
DESCRIPTION:Impedance\, differential time and tripping current test\, earth resistance meter calibration \nEPTIS ID: 882562\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: multifunctional measuring instrument\nModel / type: Metrel MI 3100 SE\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nImpedance measurement \n1. Z LINE: line impedance phase-neutral / phase (METREL MI 3100 s)\n2. Z LOOP: impedance of the fault loop phase / earth (METREL MI 3100 s)\n3. Zs rcd: impedance of the fault loop with low test current (METREL MI 3100 s) \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\n UUT setting\nNominal measurement points\n\n\n\n\nZ line\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZ loop\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZs rcd\n(0.50\, 1.80\, 5.00) Ω\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.50 Ω\n8 mΩ\n\n\n1.80 Ω\n18 mΩ\n\n\n5.00 Ω\n30 mΩ\n\n\n50.0 Ω\n0.39 Ω\n\n\n100.0 Ω\n0.50 Ω\n\n\n180 Ω\n1.0 Ω\n\n\n\n\nDifferential tripping time (RCD t) and current (RCD I) \nMeasurement points:\nTrip Out time (RCD t) \n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA X1 – AC – 0°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n300 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n30 mA X1 – AC – 180°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- Selective\n390 ms\n\n\n30 mA X2 – AC – 0°- general non delayed\n150 ms\n\n\n30 mA X5 – AC – 0°- general non delayed\n40 ms\n\n\n500 mA X5 – AC – 0°- general non delayed\n20 ms\n\n\n\nTrip Out current (RCD I)\nExecution of the points in the table to 20 ms (Trip out time reference) \n\n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA – AC – 0° – general non delayed\n10 mA\n\n\n30 mA – AC – 0° – general non delayed\n30 mA\n\n\n1000 mA – AC – 0° – general non delayed\n1000 mA\n\n\n30 mA – AC – 180° – general non delayed\n30 mA\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\nRCD trip Time\n0.020 % rdg + 0.25 ms\n\n\nRCD trip Current\n1.0 % rdg\n\n\n\n\nMeasurement of earth resistance value \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.10 Ω\n5.0 mΩ\n\n\n1.0 Ω\n10 mΩ\n\n\n10 Ω\n60 mΩ\n\n\n100 Ω\n0.50 Ω\n\n\n900 Ω\n5.0 Ω\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_01_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Metrel-MI3100-s.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20211209T171746Z
LAST-MODIFIED:20261009T103556Z
UID:676-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_02_EX
DESCRIPTION:Fault loop impedance with high current meter \nEPTIS ID: 882556\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: Loop impedance meter\nModel / type: Thytronic Impmeter2\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n80 mΩ\n3.0 mΩ\n\n\n100 mΩ\n3.0 mΩ\n\n\n130 mΩ\n3.0 mΩ\n\n\n0.20 Ω\n15 mΩ\n\n\n 0.90 Ω\n19 mΩ\n\n\n5.0 Ω\n44 mΩ\n\n\n9.0 Ω\n68 mΩ\n\n\n19 Ω\n0.13 Ω\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_02_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/Thytronic-Impmeter2.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20211210T180945Z
LAST-MODIFIED:20261009T103644Z
UID:678-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_03_EX
DESCRIPTION:DCV\, ACV dielectric strength test meter  \nEPTIS ID: 882638\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: AC/DC/IR Hipot tester\nModel: Quadtech Sentry 30 Plus\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory pr NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement points\n\nCMC\n\n\n\n\nDielectric strength DCV\n (1000\, 3000\, 5000) V\n0.30 % rdg + 5 V\n\n\nDielectric strength ACV 50 Hz\n (1000\, 3000\, 5000) V\n0.50 % rdg + 5 V\n\n\n\n\n\n\n\n\n\nMeasurement points\n\n\nCMC\n\n\n\n\nDielectric strength DCV\n1000 V\n2000 V\n5000 V\n1 mA\n4 mA\n1 mA\n0.20 % rdg\n\n\nDielectric strength ACV\n1000 V\n2000 V\n5000 V\n1 mA\n14 mA\n15 mA\n0.20 % rdg\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_03_ex/
CATEGORIES:ILC - Electrical safety
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20211210T182113Z
LAST-MODIFIED:20261009T103753Z
UID:680-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_04_EX
DESCRIPTION:Leakage current\, earth bond resistance meter \nEPTIS ID: 882600\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: PAT tester\nModel: Metrel MI2142 AlphaPAT\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\nDifferential leakage\n(2\, 5\, 10\, 15) mA\n0.3 % rdg + 2.0 µA\n\n\nTouch leakage\n(1.0\, 1.5) mA\n0.3 % rdg + 2.0 µA\n\n\n Earth bond resistance\n 500 mΩ\n 8.0 mΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_04_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/AlphaPAT.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20220525T095151Z
LAST-MODIFIED:20261009T100641Z
UID:1054-1820188800-1820275199@www.agmetrology.com
SUMMARY:PT 17043O_01 – EPTIS ID XXXXX
DESCRIPTION:Illuminance up to 400000 lx   \nItem: light meter\nModel: HT Instruments – HT 309\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\nup to 400000 lx\nReference Laboratory CMC:\nto be defined \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: September 2023 \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/pt-17043o_01-eptis-id-xxxxx/
CATEGORIES:ILC- Optical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/1_luxmetro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20241019T165231Z
LAST-MODIFIED:20261009T100012Z
UID:2455-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043T_06_AG
DESCRIPTION:Dew / frost point temperature meter calibration \nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: dew / frost point meter\nModel: General Eastern Optica + General Eastern D2\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points:\n(-25\, -15\, -5\, 5\, 15\, 25) °C \nReference Laboratory CMC:\n0.19 °C \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_06_ag/
CATEGORIES:ILC - Dew point
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/10/pt-rugiada2-e1788343653310.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20241117T165904Z
LAST-MODIFIED:20261119T112115Z
UID:2848-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_05_EX
DESCRIPTION:Insulation resistance meter \nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: insulation resistance meter\nModel / type: AEMC 5050\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\n(0.1\, 0.5\, 1.0\, 5.0\, 10\, 100\, 190) MΩ\n50 V\n0.3 % rdg\n\n\n( 0.5\, 1.0\, 5.0\, 10\, 100\, 190) MΩ\n500 V\n0.3 % rdg\n\n\n(1\, 2\, 3\, 5\, 10\, 15\, 20\, 25\, 30) MΩ\n1000 V\n1.0 % rdg\n\n\n(1\, 10\, 100\, 1000) GΩ\n5000 V\n2.0 % rdg\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_05_ex/
CATEGORIES:ILC - Electrical safety
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T151017
CREATED:20250703T172410Z
LAST-MODIFIED:20261009T104840Z
UID:3213-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043T_05_HT_EX
DESCRIPTION:Infrared thermometer calibration \nEPTIS ID: 1394698\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: infrared thermometer\nModel / type: Minolta Land Cyclops 152\nExternal provider for the calibration of the PT item:  an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n600 °C\n0.90 °C\n\n\n800 °C\n0.90 °C\n\n\n1000 °C\n1.0 °C\n\n\n1200 °C\n1.0 °C\n\n\n1400 °C\n 1.5 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: even-numbered years in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_05_ht_ex-eptis-id-1394698/
CATEGORIES:ILC - Temperature
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20211129T115504Z
LAST-MODIFIED:20261009T092814Z
UID:528-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_-95_100_kR_AG
DESCRIPTION:Pneumatic pressure transducer from -95 kPa to 100 kPa calibration\, gauge pressure \nEPTIS ID: 806743\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: GE Druck DPI150\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-95\, -80\, -60\, -40\, -20\, 0\, 20\, 40\, 60\, 80\, 100) kPa \nReference Laboratory CMC:\n|0.0019 %| rdg + 0.12 Pa (range -95 kPa to 0 kPa)\n0.0019 % rdg + 0.06 Pa (range 0 kPa to 100 kPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_-95kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/Gemini_Generated_Image_rmst6qrmst6qrmst.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20211129T143255Z
LAST-MODIFIED:20261009T092648Z
UID:545-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_7MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 7 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.0\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.40 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20211210T182810Z
LAST-MODIFIED:20261009T104641Z
UID:667-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043T_02_EX
DESCRIPTION:SPRT calibration \nEPTIS ID: 848623\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires resistance thermometer\nModel / type: Rosemount 162CE\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.005 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-848623/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/SPRT.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20231228T160035Z
LAST-MODIFIED:20261119T105055Z
UID:2126-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043T_03_PT_EX
DESCRIPTION:SPRT with Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / Item: SPRT with a Digital Readout Thermometer calibration\nModel / type: Fluke 1522 + Fluke 5609-400-G\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.004 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_03_pt_ex-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/catena-e1703780406498.jpeg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20241102T083030Z
LAST-MODIFIED:20261009T093036Z
UID:2586-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_-25_25kR_AG
DESCRIPTION:Pneumatic pressure transducer from -25 kPa to 25 kPa calibration\, gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0004\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-25\, -20\, -15\, -10\, 0\, 5\, 10\, 15\, 20\, 25) kPa \nReference Laboratory CMC:\n|0.0019 %| rdg + 0.12 Pa (range -25 kPa to 0 kPa)\n0.0019 % rdg + 0.06 Pa (range 0 kPa to 25 kPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_25kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0004.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20241102T084057Z
LAST-MODIFIED:20261009T094717Z
UID:2589-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_170kA_AG
DESCRIPTION:Pneumatic pressure transducer from 1.4 kPa to 170 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: Paroscientific 745\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(1.4\, 17.0\, 34.0\, 51.0\, 68.0\, 85.0\, 102.0\, 119.0\, 136.0\, 153.0\, 170.0) kPa \nReference Laboratory CMC:\n0.0019 % rdg + 0.29 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_170ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20241102T092403Z
LAST-MODIFIED:20261009T094406Z
UID:2597-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_350kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 350 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DHI RPM1-G0100-R\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 35\, 70\, 105\, 140\, 175\, 210\, 245\, 280\, 315\, 350) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_350kr_ag/
CATEGORIES:ILC - Pressure
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20241102T092926Z
LAST-MODIFIED:20261009T093338Z
UID:2601-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 700 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0100\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0100.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151017
CREATED:20241102T093904Z
LAST-MODIFIED:20261009T095023Z
UID:2603-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kA_AG
DESCRIPTION:Pneumatic pressure transducer from 12 kPa to 700 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: ‘Paroscientific Digiquartz 715 + Paroscientific Digiquartz 6000-100A\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(12\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0017 % rdg + 0.31 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-715-6000-100A.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151018
CREATED:20241102T094759Z
LAST-MODIFIED:20261009T093433Z
UID:2606-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 3.5 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: CalRef Cube-P\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.40 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Cube-P.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151018
CREATED:20241102T095222Z
LAST-MODIFIED:20261009T095157Z
UID:2608-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.17 MPa to 3.5 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 A0500\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.17\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-A0500.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151018
CREATED:20241102T095819Z
LAST-MODIFIED:20261009T095255Z
UID:2611-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_7MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.2 MPa to 7 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.2\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261122T151018
CREATED:20241102T100749Z
LAST-MODIFIED:20261119T115234Z
UID:2617-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_20MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 20 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific 745-3K\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 2\, 4\, 6\, 8\, 10\, 12\, 14\, 16\, 18\, 20) MPa \nReference Laboratory CMC: \n0.005 5 % rdg + 1.8 kPa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_20mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
END:VCALENDAR