BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20260101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260920T225333
CREATED:20241102T095819Z
LAST-MODIFIED:20260909T153050Z
UID:2611-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_7MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.2 MPa to 7 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.2\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260920T225333
CREATED:20241102T100749Z
LAST-MODIFIED:20260520T141034Z
UID:2617-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_20MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 20 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific 745-3K\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 2\, 4\, 6\, 8\, 10\, 12\, 14\, 16\, 18\, 20) MPa \nReference Laboratory CMC: \n0.005 5 % rdg + 1.8 kPa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_20mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260920T225333
CREATED:20211204T172346Z
LAST-MODIFIED:20260909T153909Z
UID:572-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_35MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 35 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 3.5\, 7.0\, 10.5\, 14.0\, 17.5\, 21.0\, 24.5\, 28.0\, 31.5\, 35.0) MPa \nReference Laboratory Measurement:\n0.0076 % rdg + 2.0 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_35mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260920T225333
CREATED:20241102T102317Z
LAST-MODIFIED:20260520T122311Z
UID:2624-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_100MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 100 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific DigiQuartz 735 + Paroscientific DigiQuartz 415K-101\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60\, 70\, 80\, 90\, 100) MPa \nReference Laboratory Measurement:\n0.0055 % rdg + 2.2 Pa (up to 6 MPa)\n0.0076 % rdg + 2.0 Pa (range 6 MPa to 120 MPa) \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_100mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-415K-101.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260920T225333
CREATED:20241102T103452Z
LAST-MODIFIED:20260520T141210Z
UID:2629-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_280MR_EX
DESCRIPTION:Hydraulic pressure transducer up to 280 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM4 A280Ms-L\nReference Laboratory: NMI or Accreditated Laboratory according to ISO IEC 17025 in MRA field \nMeasurement Points:\n(0\, 28\, 56\, 84\, 112\, 140\, 168\, 196\, 224\, 252\, 280) MPa \nReference Laboratory CMC:\n0.0051 % rdg + 2.7 kPa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_280mr_ex/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260920T225333
CREATED:20220522T155757Z
LAST-MODIFIED:20260421T074456Z
UID:1035-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043M_01_EX
DESCRIPTION:Set of weights class E2 from 1 mg to 10 kg  \nEPTIS ID: 935474\nPT scheme / program name: Mass calibration\nPT item type: Mass\nSample / item: weights\nModel: class E2\, from 1 mg to 10 kg\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n1 mg\, 10 mg\, 100 mg\, 1 g\, 10 g\, 100 g\, 1 kg\, 2 kg\, 5 kg\, 10 kg\nReference Laboratory CMC: \n\n\n\n\n\nMass\nCMC\n\n\n\n\n1 mg\n0.001 mg\n\n\n10 mg\n0.001 mg\n\n\n100 mg\n0.0016 mg\n\n\n1 g\n0.003 mg\n\n\n10 g\n0.006 mg\n\n\n100 g\n0.016 mg\n\n\n1 kg\n0.15 mg\n\n\n2 kg\n0.3 mg\n\n\n5 kg\n0.8 mg\n\n\n10 kg\n1.5 mg\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043m_01_ex/
CATEGORIES:ILC - Mass
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_masse.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260920T225333
CREATED:20220522T161041Z
LAST-MODIFIED:20260421T074425Z
UID:1038-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_02_EX
DESCRIPTION:Air velocity meter from 2.0 m/s to 30 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer\nModel / type: TSI Velocical 9535\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n(2.0\, 5.0\, 7.0\, 15\, 23\, 30) m/s\nReference Laboratory CMC:\n0.47 % rdg + 0.004 m/s \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_02_ex/
CATEGORIES:ILC - Air Velocity
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_anemometro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260920T225333
CREATED:20220525T100535Z
LAST-MODIFIED:20260421T074716Z
UID:1057-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043A_01_EX
DESCRIPTION:Sound Level Meter  \nEPTIS ID: 941623\nPT scheme / program name: Acoustic calibration\nPT item type: Sound Level Meter\nSample / item: acoustical measuring equipment\nModel: Bruel & Kjaer 2238 Mediator\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points: \n\nSelf generated noise\, range (0 – 80) dB\, Mode Leq\nAcoustical signal tests of frequency weighting\, range (50 – 130) dB\, Frequency Weighting setting C\, Time Weighting response Slow\nElectrical signal tests of frequency weightings\, range (50 – 130) dB\nFrequency and time weightings at 1 kHz\, range (50 – 130) dB\nLevel linearity on the reference level range\, range (50 – 130) dB\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nLevel linearity including the level range control\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nToneburst response\, range (50 – 130) dB\nC-weighted peak sound level\, range: (60 – 140) dB\nOverload indication\, Range: (60 – 140) dB\, SLM Measuring Mode LAEq\n\nReference Laboratory CMC: \n\nSound calibrators \, Sound pressure level : 84 dB (reference: 20 µPa)\nSound calibrator\, single frequency 1 kHz 0.26 dB\nSound calibrators \, Sound pressure level : 124 dB (reference: 20 µPa)\nPistonphone\, single frequency 250 Hz 0.12 dB\nSound measuring instruments \, Sound pressure response level : 94 dB (reference: 20 µPa) Sound level meter 0.30 dB\nSound calibrators \, Sound pressure level : 94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa) Sound calibrator\, single frequency 1 kHz 0.13 dB\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043a_01_ex/
CATEGORIES:ILC - Acoustic
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/1_fonometro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260920T225333
CREATED:20241117T171846Z
LAST-MODIFIED:20260421T074406Z
UID:2854-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_01_EX
DESCRIPTION:Air velocity meter from 0.2 m/s to 2.0 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: air flow\nSample / item: anemometer\nModel / type: Ahlborn Almemo 2590 + FVAD 35 TH4\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n(0.20\, 0.50\, 1.0\, 1.5\, 2.0) m/s\nReference Laboratory CMC:\n0.47 % rdg + 0.004 m/s \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_01_ex/
CATEGORIES:ILC - Air Velocity
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260920T225333
CREATED:20241117T172701Z
LAST-MODIFIED:20260421T074346Z
UID:2857-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_03_EX
DESCRIPTION:Air velocity meter from 30 m/s to 60 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer (pitot tube)\nModel / type: Delta Ohm HD2134P.2 + Delta Ohm T1-300\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n(30\, 40\, 50\, 60) m/s\nReference Laboratory CMC:\n2.4 % rdg \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_03_ex/
CATEGORIES:ILC - Air Velocity
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270201
DTEND;VALUE=DATE:20270202
DTSTAMP:20260920T225333
CREATED:20251102T160948Z
LAST-MODIFIED:20260902T100604Z
UID:3628-1801440000-1801526399@www.agmetrology.com
SUMMARY:17043T_03_-40_150_PT_AG
DESCRIPTION:Pt100 with a Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: Pt100 with a digital readout thermometer calibration\nModel: Ahlborn Almemo 2590 + NALEO Pt100/W-P-A4F-Ø4×200-A6-BT2-PFA/SCH/22/1000/FL/IEC-MOLLA-XX\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-40 °C\n0.019 °C\n\n\n-18 °C\n0.019 °C\n\n\n0 °C\n0.005 °C\n\n\n4 °C\n0.019 °C\n\n\n25 °C\n0.019 °C\n\n\n37 °C\n0.019 °C\n\n\n45 °C\n0.019 °C\n\n\n80 °C\n0.029 °C\n\n\n100 °C\n0.029 °C\n\n\n121 °C\n0.029 °C\n\n\n150 °C\n0.029 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in February \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043t_03_-40_150_pt_ag/
CATEGORIES:ILC - Temperature
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225333
CREATED:20211129T142854Z
LAST-MODIFIED:20260729T093657Z
UID:541-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043U_01_AG
DESCRIPTION:Calibration of Relative Humidity environmental conditions in air \nEPTIS ID: 708000\nPT scheme / program name: Thermodynamic calibration\nPT item type: Relative humidity\nSample / item: thermohygrometer\nModel: Rotronic HygroPalm HP32 + Rotronic HC2A-IC102\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n10 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n20 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n30 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n40 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n50 °C isotherm (10\, 30\, 50\, 70) % RH \nReference Laboratory CMC:\n1.4 % rdg + 0.37% R.H. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043u_01_ag/
CATEGORIES:ILC - Humidity
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/1648621320179-scaled-e1788343206379.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20211205T165512Z
LAST-MODIFIED:20260729T093640Z
UID:605-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCL_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nEPTIS ID: 882510\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp with display for low currents AC / DC\nModel: UNI-T UT211B\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI\nMeasurement points: \nDCI \nRange 6000 mA ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nACI \nRange 600.0 mA 50 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 100 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 400 Hz ⇒ (60.0\, 540.0) mA\n6000 mA 50 Hz ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nReference Laboratory CMC:\nRange 1 µA < I ≤ 1 A ⇒ da 2.5 x 10-5 x I a 1.4 x 10-5 x I\n1 A < I ≤ 10 A ⇒ da 1.4 x 10-5 x I a 1.7 x 10-5 x I \nRange 2.5 mA < I ≤ 3 A 40 Hz ≤ f ≤ 10 kHz ⇒ 1.3 X 10-4 X I\n50 mA < I ≤ 100 A 40 Hz ≤ f ≤ 60 Hz ⇒ 1.3 X 10-4 X I \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_ccl_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCL-1.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20211205T171248Z
LAST-MODIFIED:20260421T074623Z
UID:609-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCT_EX
DESCRIPTION:Current clamp transducer AC  calibration \nEPTIS ID: 882534\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp transducer AC\nModel: Hioki CT9667-02\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\nRange 500 A (1mV AC / A) 50 Hz    ⇒     (50\, 450) A\nRange 5000 A (0.1 mV AC / A) 50 Hz     ⇒     (500\, 1500\, 2500\, 3500\, 4500) A \nReference Laboratory CMC: \n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤ f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n  100 A < I ≤ 240 A\n40 Hz ≤ f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n 240 A < I ≤ 10 kA\n40 Hz ≤ f ≤ 60 Hz\n1.0 x 10^-4 x I\n\n\n\n\nNote:Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cct_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCT-HIOKI.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20211205T173620Z
LAST-MODIFIED:20260421T074603Z
UID:614-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCH_EX
DESCRIPTION:Current clamp with display for high currents AC / DC \nEPTIS ID: 882516\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: Current clamp with display for high currents AC / DC\nModel: ASITA DURA PA610\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points: \n\n\nDCI \n\n\n\nRange\n60.00 A\n6.00 A\, 54.00 A\n\n\n\n\n\n600.00 A\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A\n100 A\, 900 A\n\n\n\n\n\n\nACI \n\n\n\nRange\n60.00 A 50 Hz\n6.00 A\, 54.00 A\n\n\n\n\n\n60.00 A 100 Hz\n6.00 A\n\n\n\n60.00 A 400 Hz\n6.00 A\n\n\n\n600.0 A 50 Hz\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A 50 Hz\n100 A\, 900 A\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nRange\n1 A < I ≤ 10 A\nda 1.4 x 10^-5 x I a 1.7 x 10^-5 x I\n\n\n\n\n\n10 A < I ≤ 100 A\nda 1.7 x 10^-5 x I a 4.8 x 10^-5 x I\n\n\n\n100 A < I ≤ 300 A\n1.2 x 10^-4 x I\n\n\n\n300 A < I ≤ 1750 A\n4.4 x 10^-4 x I\n\n\n\n\n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n3 A < I ≤ 20 A\n40 Hz ≤f ≤10 kHz\n2.0 x 10^-4 x I\n\n\n\n 100 A < I ≤ 240 A\n40 Hz ≤f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n240 A < I ≤ 1000 A\n40 Hz ≤f ≤ 60 Hz\n1.0 x 10^-3 x I\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment:bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cch_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCH.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20211208T093610Z
LAST-MODIFIED:20260902T100332Z
UID:651-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_03_N_AG
DESCRIPTION:N type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: N type thermocouple with digital readout thermometer\nModel / type: Beamex MC2-TE + N type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.25 °C\n\n\n400 °C\n0.25 °C\n\n\n500 °C\n0.27 °C\n\n\n600 °C\n0.27 °C\n\n\n700 °C\n 1.1 °C\n\n\n800 °C\n 1.1 °C\n\n\n900 °C\n 1.1 °C\n\n\n1000 °C\n 1.1 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_n-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_03_N_AG-e1788343344137.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20211208T161357Z
LAST-MODIFIED:20260902T100048Z
UID:663-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_07_AG
DESCRIPTION:In air temperature meter calibration \nEPTIS ID: 707603\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermo hygrometer\nModel / type: Rotronic HygroPalm 32 + Rotronic HC2A-S\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60) °C \nReference Laboratory CMC:\n0.15 °C \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_07-eptis-id-707603/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/1648621320179-scaled-e1788343206379.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T225334
CREATED:20231228T154820Z
LAST-MODIFIED:20260902T095608Z
UID:2124-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_01_N_AG
DESCRIPTION:N type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: N type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.23 °C\n\n\n400 °C\n0.24 °C\n\n\n500 °C\n0.26 °C\n\n\n600 °C\n0.26 °C\n\n\n700 °C\n 1.1 °C\n\n\n800 °C\n 1.1 °C\n\n\n900 °C\n 1.1 °C\n\n\n1000 °C\n 1.1 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043t_01_n_ag/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/Termocoppia-N-Nicrobel-scaled-e1788342892949.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20211129T115019Z
LAST-MODIFIED:20260729T093618Z
UID:523-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_AG
DESCRIPTION:6½ digit DMM DC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM DC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n100 mV\n0.0013 % rdg + 0.98 µV\n(-90\, 0\, 10\, 90) mV\n\n\n1 V\n0.0013 % rdg + 2.0 µV\n(-0.9\, 0.1\, 0.9) V\n\n\n10 V\n0.00092 % rdg + 12 µV\n(-9\, -5\, -1\, 1\, 3\, 5\, 7\, 9) V\n\n\n100 V\n0.0012 % rdg + 0.18 mV\n(-90\, 10\, 90) V\n\n\n1000 V\n0.00034 % rdg + 14 mV\n(-900\, 100\, 900) V\n\n\nIN DCI RANGE\n\n\n\n\n100 µA\n0.0065% rdg + 0.19 µA\n(0\, 10\, 90) µA\n\n\n1 mA\n0.011% rdg + 2.2 µA\n(0.1\, 0.9) mA\n\n\n10 mA\n0.019% rdg + 50 µA\n(1\, 9) mA\n\n\n100 mA\n0.019% rdg + 50 µA\n(-90\, 10\, 90) mA\n\n\n1 A\n0.019% rdg + 50 µA\n(0.1\, 0.9) A\n\n\n10 A\n0.019% rdg + 50 µA\n(1 A\, 9) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.0075 % rdg + 15 µΩ\n(0\, 1\, 10) Ω\n\n\n100 Ω\n0.0021 % rdg + 45 µΩ\n(10\, 100) Ω\n\n\n1 kΩ\n0.0020 % rdg + 0.67 mΩ\n(0.1\, 1.0) kΩ\n\n\n10 kΩ\n0.0020 % rdg + 5.6 mΩ\n(1\, 10) kΩ\n\n\n100 kΩ\n0.0022 % rdg + 0.38 Ω\n(10\, 100) kΩ\n\n\n1 MΩ\n0.0034 % rdg + 0.45 Ω\n(0.1\, 1.0) MΩ\n\n\n10 MΩ\n0.0053 % rdg + 0.19 kΩ\n(1\, 10) MΩ\n\n\n100 MΩ\n0.035 % rdg + 20 kΩ\n(10\, 100) MΩ\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_01_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20211129T115317Z
LAST-MODIFIED:20260729T093546Z
UID:525-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_03_AG
DESCRIPTION:6½ digit DMM\, AC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM AC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 900 V from 50 Hz up to 100 kHz\n\n\n\n\n100 mV\n\n\n\n\n1 kHz\n0.034% rdg + 18 µV\n(10\, 90) mV\n\n\n50 Hz\n0.034% rdg + 18 µV\n90 mV\n\n\n20 kHz\n0.046% rdg + 27 µV\n90 mV\n\n\n(50\, 100) kHz\n0.18% rdg + 46 µV\n90 mV\n\n\n1 V\n\n\n\n\n(0.05\, 1) kHz\n0.029% rdg + 0.11 mV\n0.9 V\n\n\n20 kHz\n0.030% rdg + 0.11 mV\n0.9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 0.41 mV\n0.9 V\n\n\n10 V\n\n\n\n\n1 kHz\n0.029% rdg + 1.1 mV\n(1\, 5\, 9) V\n\n\n(0.05\, 20) kHz\n0.029% rdg + 1.1 mV\n9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 4.1 mV\n9 V\n\n\n100 V\n\n\n\n\n(0.05\, 1\, 20) kHz\n0.025% rdg + 11 mV\n90 V\n\n\n(50\, 100) kHz\n0.11% rdg + 41 mV\n90 V\n\n\n1000 V\n\n\n\n\n50 Hz\n0.037% rdg + 0.16 V\n900 V\n\n\n(5\, 10) kHz\n0.035% rdg + 0.25 V\n900 V\n\n\nACI up to 9 A from 20 Hz up to 5 kHz\n\n\n\n\n100 µA\n\n\n\n\n(0.05\, 1) kHz\n0.041 % rdg + 33 nA\n(10\, 90) µA\n\n\n5 kHz\n0.041 % rdg + 33 nA\n90 µA\n\n\n1 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 0.24 µA\n0.9 mA\n\n\n10 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 2.7 µA\n9 mA\n\n\n100 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 27 µA\n90 mA\n\n\n1 A\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.17 % rdg + 0.84 mA\n0.9 A\n\n\n10 A\n\n\n\n\n(0.05\, 1) kHz\n0.36 % rdg + 15 mA\n9 A\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_03_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20211207T100657Z
LAST-MODIFIED:20260729T093526Z
UID:629-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043T_01_S_AG
DESCRIPTION:S type thermocouple calibration \nEPTIS ID: 797767\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: thermocouple\nModel / type: S type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.19 °C\n\n\n400 °C\n0.19 °C\n\n\n500 °C\n0.22 °C\n\n\n600 °C\n0.22 °C\n\n\n700 °C\n0.51 °C\n\n\n800 °C\n0.51 °C\n\n\n900 °C\n0.51 °C\n\n\n1000 °C\n0.51 °C\n\n\n1080 °C\n0.51 °C\n\n\n1200 °C\n1.2 °C\n\n\n1300 °C\n1.2 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797767/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/ILC-TC-S.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20250105T111709Z
LAST-MODIFIED:20260729T093505Z
UID:2957-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_02_AG
DESCRIPTION:5½ digit multifunction calibrator DC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator DC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n10 mV\n0.0011 % rdg + 0.49 µV\n(-10\, -1\, 1\, 10) mV\n\n\n100 mV\n0.0011 % rdg + 0.49 µV\n(-100\, -10\, 10\, 100) mV\n\n\n1 V\n0.00083 % rdg + 1.8 µV\n(-1.0\, -0.1\, 0.1\, 0.2\, 0.3\, 0.4\, 0.5\, 0.6\, 0.7\, 0.8\, 0.9\, 1.0) V\n\n\n10 V\n0.00072 % rdg + 6.3 µV\n(-10\, -1\, 1\, 10) V\n\n\n100 V\n0.00083 % rdg + 0.12 mV\n(-100\, -10\, 10\, 100) V\n\n\n1000 V\n0.0011 % rdg + 2.1 mV\n(-1000\, -100\, 100\, 1000) V\n\n\nIN DCI RANGE\n\n\n\n\n200 µA\n0.0051 % rdg + 1.3 nA up to 100 µA \n0.0051 % rdg + 7.9 nA above 100 µA\n(-200\, -20\, 20\, 200) µA\n\n\n2 mA\n0.0051 % rdg + 7.9 nA up to 1 mA \n0.0051 % rdg + 79 nA above 1 mA\n(-2.0\, -0.2\, 0.2\, 2.0) mA\n\n\n20 mA\n0.0051 % rdg + 79 nA up to 10 mA \n0.011 % rdg + 1.3 µA above 10 mA\n(-20\, -2. 2\, 20) mA\n\n\n200 mA\n0.011 % rdg + 1.3 µA up to 100 mA \n0.016 % rdg + 24 µA above 100 mA\n(-200\, -20\, 20\, 200) mA\n\n\n2 A\n0.016 % rdg + 24 µA up to 1 A \n0.0041 % rdg + 0.11 mA above 1 A\n(-2.0\, -0.2\, 0.2\, 2.0) A\n\n\n20 A\n0.0041 % rdg + 0.11 mA\n(-20\, -2\, 2\, 20) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.011 % rdg + 0.11 mΩ\n10 Ω\n\n\n100 Ω\n0.0029 % rdg + 0.42 mΩ\n100 Ω\n\n\n1.0 kΩ\n0.0026 % rdg + 4.2 mΩ\n1.0 kΩ\n\n\n10 kΩ\n0.0026 % rdg + 42 mΩ\n10 kΩ\n\n\n100 kΩ\n0.0026 % rdg + 0.42 Ω\n100 kΩ\n\n\n1 MΩ\n0.0036 % rdg + 5.4 Ω\n1.0 MΩ\n\n\n10 MΩ\n0.021 % rdg + 0.23 kΩ\n10 MΩ\n\n\n100 MΩ\n0.073 % rdg + 15 kΩ\n100 MΩ\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_02_ag/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20250105T115704Z
LAST-MODIFIED:20260729T093425Z
UID:2962-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_04_AG
DESCRIPTION:5½ digit multifunction calibrator\, AC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator AC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 1000 V from 40 Hz up to 10 kHz\n\n\n\n\n10 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n10 mV\n\n\n100 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n100 mV\n\n\n1 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 17 µV\n 1 V\n\n\n10 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 0.17 mV\n10 V\n\n\n100 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.009 7 % rdg + 1.4 mV\n100 V\n\n\n1000 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.012 % rdg + 12 mV\n1000 V\n\n\nACI up to 20 A from 20 Hz up to 1 kHz\n\n\n\n\n200 µA\n\n\n\n\n(0.02\, 0.20\, 1.00) kHz\n0.017 % rdg + 0.20 µA\n200 µA\n\n\n2 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 2.0 µA\n2 mA\n\n\n20 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 20 µA\n20 mA\n\n\n200 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.10 % rdg + 0.70 mA\n200 mA\n\n\n2 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.003 4 % rdg + 1.5 mA\n2 A\n\n\n20 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.005 0 % rdg + 3.7 mA\n20 A\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_04_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2025/01/Meatest-M143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20260920T225334
CREATED:20260116T181831Z
LAST-MODIFIED:20260729T093341Z
UID:3784-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_10E-6O_EX
DESCRIPTION:Micro-ohmmeter Resistance calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: micro ohmmeter\nModel: Valhalla Scientific 4300B\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\n RANGE\nCMC\nMeasurement Points\n\n\n\n\n2.0000 mΩ (test current 10 A)\n20 ppm RDG\n(0.0000\, 1.0000) mΩ\n\n\n20.000 mΩ (test current 10 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n20.000 mΩ (test current 1 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n200.00 mΩ (test current 1 A)\n5 ppm RDG\n(0.00\, 100.00) mΩ\n\n\n200.00 mΩ (test current 0.1 A)\n5 ppm RDG\n(0.000\, 100.00) mΩ\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043e_01_10e-6o_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2026/01/Valhalla-4300B.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T225334
CREATED:20211205T111916Z
LAST-MODIFIED:20260729T093323Z
UID:599-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043E_05_AG
DESCRIPTION:Temperature calibrator calibration \nEPTIS ID: 703492\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: temperature calibrator\nModel / type: Beamex MC5\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type S\n0.11 – 0.0022 % rdg °C with 0° C RJ\n0.17 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Simulation use with Thermocouple Type S\n0.032 °C + 0.0012 % rdg with 0° C RJ\n0.14 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type T\n0.029 °C – 0.0033 % rdg with 0° C RJ\n0.13 °C – 0.0083 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Simulation use with Thermocouple Type T\n0.015 °C with 0° C RJ\n0.13 °C – 0.0067 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with RTD\n0.0020 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\nTemperature Simulation use with RTD\n0.0019 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_05_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Beamex-MC5.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T225334
CREATED:20211208T095445Z
LAST-MODIFIED:20260902T095331Z
UID:654-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_02_AG
DESCRIPTION:IPRT Calibration \nEPTIS ID: 708010\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires IPRT\nModel / type: Klasmeier eXacal Pt100 IH\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.085 °C\n\n\n-80 °C\n0.017 °C\n\n\n-60 °C\n0.017 °C\n\n\n-40 °C\n0.017 °C\n\n\n-20 °C\n0.017 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.031 °C\n\n\n100 °C\n0.028 °C\n\n\n150 °C\n0.028 °C\n\n\n200 °C\n0.028 °C\n\n\n250 °C\n0.028 °C\n\n\n300 °C\n0.028 °C\n\n\n400 °C\n0.072 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-708010/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_02_AG-e1788342730139.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20260920T225334
CREATED:20211208T152820Z
LAST-MODIFIED:20260902T094552Z
UID:659-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_03_PT_AG
DESCRIPTION:IPRT with a Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: IPRT with a Digital Readout Thermometer calibration\nModel: Fluke 1502A + Fluke 5609\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.086 °C\n\n\n-80 °C\n0.019 °C\n\n\n-60 °C\n0.019 °C\n\n\n-40 °C\n0.019 °C\n\n\n-20 °C\n0.019 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.019 °C\n\n\n100 °C\n0.029 °C\n\n\n150 °C\n0.029 °C\n\n\n200 °C\n0.029 °C\n\n\n250 °C\n0.029 °C\n\n\n300 °C\n0.029 °C\n\n\n400 °C\n0.073 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/1502A-SPRT-scaled-e1788342253645.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20260920T225334
CREATED:20211129T143141Z
LAST-MODIFIED:20260902T093706Z
UID:543-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_01_T_AG
DESCRIPTION:T type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.14 °C\n\n\n-80 °C\n0.14 °C\n\n\n-60 °C\n0.14 °C\n\n\n-40 °C\n0.14 °C\n\n\n-20 °C\n0.14 °C\n\n\n0 °C\n0.069 °C\n\n\n50 °C\n0.069 °C\n\n\n100 °C\n0.14 °C\n\n\n150 °C\n0.14 °C\n\n\n200 °C\n0.14 °C\n\n\n250 °C\n0.14 °C\n\n\n300 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797772/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/17043T_01_T_AG-e1788341313143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20260920T225334
CREATED:20211207T102108Z
LAST-MODIFIED:20260902T100907Z
UID:633-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_03_T_AG
DESCRIPTION:T type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: digital readout with thermocouple\nModel / type: digital readout Beamex MC2-TE + T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.16 °C\n\n\n-80 °C\n0.16 °C\n\n\n-60 °C\n0.16 °C\n\n\n-40 °C\n0.16 °C\n\n\n-20 °C\n0.16 °C\n\n\n0 °C\n0.075 °C\n\n\n50 °C\n0.075 °C\n\n\n100 °C\n0.17 °C\n\n\n150 °C\n0.17 °C\n\n\n200 °C\n0.17 °C\n\n\n250 °C\n 0.17 °C\n\n\n300 °C\n 0.17 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_t-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_03_T_AG-e1788341141821.jpg
END:VEVENT
END:VCALENDAR