BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20260101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20261122T145940
CREATED:20220522T155757Z
LAST-MODIFIED:20261001T092943Z
UID:1035-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043M_01_EX
DESCRIPTION:Set of weights class E2 from 1 mg to 10 kg  \nEPTIS ID: 935474\nPT scheme / program name: Mass calibration\nPT item type: Mass\nSample / item: weights\nModel: class E2\, from 1 mg to 10 kg\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\n1 mg\, 10 mg\, 100 mg\, 1 g\, 10 g\, 100 g\, 1 kg\, 2 kg\, 5 kg\, 10 kg\nCMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMass\nCMC\n\n\n\n\n1 mg\n0.001 mg\n\n\n10 mg\n0.001 mg\n\n\n100 mg\n0.0016 mg\n\n\n1 g\n0.003 mg\n\n\n10 g\n0.006 mg\n\n\n100 g\n0.016 mg\n\n\n1 kg\n0.15 mg\n\n\n2 kg\n0.3 mg\n\n\n5 kg\n0.8 mg\n\n\n10 kg\n1.5 mg\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043m_01_ex/
CATEGORIES:ILC - Mass
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_masse.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20261122T145940
CREATED:20220522T161041Z
LAST-MODIFIED:20261001T092919Z
UID:1038-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_02_EX
DESCRIPTION:Air velocity meter from 2.0 m/s to 30 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer\nModel / type: TSI Velocical 9535\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\n(2.0\, 5.0\, 7.0\, 15\, 23\, 30) m/s\nCMC from the calibration laboratory’s accreditation schedule:\n0.47 % rdg + 0.004 m/s \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_02_ex/
CATEGORIES:ILC - Air Velocity
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_anemometro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20261122T145941
CREATED:20220525T100535Z
LAST-MODIFIED:20261001T092857Z
UID:1057-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043A_01_EX
DESCRIPTION:Sound Level Meter  \nEPTIS ID: 941623\nPT scheme / program name: Acoustic calibration\nPT item type: Sound Level Meter\nSample / item: acoustical measuring equipment\nModel: Bruel & Kjaer 2238 Mediator\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points: \n\nSelf generated noise\, range (0 – 80) dB\, Mode Leq\nAcoustical signal tests of frequency weighting\, range (50 – 130) dB\, Frequency Weighting setting C\, Time Weighting response Slow\nElectrical signal tests of frequency weightings\, range (50 – 130) dB\nFrequency and time weightings at 1 kHz\, range (50 – 130) dB\nLevel linearity on the reference level range\, range (50 – 130) dB\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nLevel linearity including the level range control\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nToneburst response\, range (50 – 130) dB\nC-weighted peak sound level\, range: (60 – 140) dB\nOverload indication\, Range: (60 – 140) dB\, SLM Measuring Mode LAEq\n\nCMC from the calibration laboratory’s accreditation schedule: \n\nSound calibrators \, Sound pressure level : 84 dB (reference: 20 µPa)\nSound calibrator\, single frequency 1 kHz 0.26 dB\nSound calibrators \, Sound pressure level : 124 dB (reference: 20 µPa)\nPistonphone\, single frequency 250 Hz 0.12 dB\nSound measuring instruments \, Sound pressure response level : 94 dB (reference: 20 µPa) Sound level meter 0.30 dB\nSound calibrators \, Sound pressure level : 94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa) Sound calibrator\, single frequency 1 kHz 0.13 dB\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043a_01_ex/
CATEGORIES:ILC - Acoustic
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/1_fonometro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20261122T145941
CREATED:20241117T171846Z
LAST-MODIFIED:20261001T092519Z
UID:2854-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_01_EX
DESCRIPTION:Air velocity meter from 0.2 m/s to 2.0 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: air flow\nSample / item: anemometer\nModel / type: Ahlborn Almemo 2590 + FVAD 35 TH4\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\n(0.20\, 0.50\, 1.0\, 1.5\, 2.0) m/s \nCMC from the calibration laboratory’s accreditation schedule:\n0.47 % rdg + 0.004 m/s \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_01_ex/
CATEGORIES:ILC - Air Velocity
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20261122T145941
CREATED:20241117T172701Z
LAST-MODIFIED:20261001T092540Z
UID:2857-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_03_EX
DESCRIPTION:Air velocity meter from 30 m/s to 60 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer (pitot tube)\nModel / type: Delta Ohm HD2134P.2 + Delta Ohm T1-300 \nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points: \n(30\, 40\, 50\, 60) m/s \nCMC from the calibration laboratory’s accreditation schedule:\n2.4 % rdg \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nAir velocity meter from 30 m/s to 60 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer (pitot tube)\nModel / type: Delta Ohm HD2134P.2 + Delta Ohm T1-300 \nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory pr NMI\, used by AG Metrology (PT provider) todetermine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule:                                                                                                         (30\, 40\, 50\, 60) m/s\nReference Laboratory CMC:\n2.4 % rdg \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_03_ex/
CATEGORIES:ILC - Air Velocity
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270201
DTEND;VALUE=DATE:20270202
DTSTAMP:20261122T145941
CREATED:20251102T160948Z
LAST-MODIFIED:20261119T105115Z
UID:3628-1801440000-1801526399@www.agmetrology.com
SUMMARY:17043T_03_-40_150_PT_AG
DESCRIPTION:Pt100 with a Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: Pt100 with a digital readout thermometer calibration\nModel: Ahlborn Almemo 2590 + NALEO Pt100/W-P-A4F-Ø4×200-A6-BT2-PFA/SCH/22/1000/FL/IEC-MOLLA-XX\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-40 °C\n0.019 °C\n\n\n-18 °C\n0.019 °C\n\n\n0 °C\n0.005 °C\n\n\n4 °C\n0.019 °C\n\n\n25 °C\n0.019 °C\n\n\n37 °C\n0.019 °C\n\n\n45 °C\n0.019 °C\n\n\n80 °C\n0.029 °C\n\n\n100 °C\n0.029 °C\n\n\n121 °C\n0.029 °C\n\n\n150 °C\n0.029 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in February \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_03_-40_150_pt_ag/
CATEGORIES:ILC - Temperature
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211129T142854Z
LAST-MODIFIED:20261009T091347Z
UID:541-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043U_01_AG
DESCRIPTION:Calibration of Relative Humidity environmental conditions in air \nEPTIS ID: 708000\nPT scheme / program name: Thermodynamic calibration\nPT item type: Relative humidity\nSample / item: thermohygrometer\nModel: Rotronic HygroPalm HP32 + Rotronic HC2A-IC102\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n10 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n20 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n30 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n40 °C isotherm (10\, 30\, 50\, 70\, 90) % RH\n50 °C isotherm (10\, 30\, 50\, 70) % RH \nReference Laboratory CMC:\n1.4 % rdg + 0.37% R.H. \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043u_01_ag/
CATEGORIES:ILC - Humidity
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/1648621320179-scaled-e1788343206379.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211205T165512Z
LAST-MODIFIED:20261001T093348Z
UID:605-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCL_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nEPTIS ID: 882510\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp with display for low currents AC / DC\nModel: UNI-T UT211B\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value\nMeasurement points: \nDCI \nRange 6000 mA ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nACI \nRange 600.0 mA 50 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 100 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 400 Hz ⇒ (60.0\, 540.0) mA\n6000 mA 50 Hz ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nCMC from the calibration laboratory’s accreditation schedule:\nRange 1 µA < I ≤ 1 A ⇒ da 2.5 x 10-5 x I a 1.4 x 10-5 x I\n1 A < I ≤ 10 A ⇒ da 1.4 x 10-5 x I a 1.7 x 10-5 x I \nRange 2.5 mA < I ≤ 3 A 40 Hz ≤ f ≤ 10 kHz ⇒ 1.3 X 10-4 X I\n50 mA < I ≤ 100 A 40 Hz ≤ f ≤ 60 Hz ⇒ 1.3 X 10-4 X I \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_ccl_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCL-1.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211205T171248Z
LAST-MODIFIED:20261001T093321Z
UID:609-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCT_EX
DESCRIPTION:Current clamp transducer AC  calibration \nEPTIS ID: 882534\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp transducer AC\nModel: Hioki CT9667-02\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\nRange 500 A (1mV AC / A) 50 Hz    ⇒     (50\, 450) A\nRange 5000 A (0.1 mV AC / A) 50 Hz     ⇒     (500\, 1500\, 2500\, 3500\, 4500) A \nCMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤ f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n  100 A < I ≤ 240 A\n40 Hz ≤ f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n 240 A < I ≤ 10 kA\n40 Hz ≤ f ≤ 60 Hz\n1.0 x 10^-4 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cct_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCT-HIOKI.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211205T173620Z
LAST-MODIFIED:20261001T093257Z
UID:614-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCH_EX
DESCRIPTION:Current clamp with display for high currents AC / DC \nEPTIS ID: 882516\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: Current clamp with display for high currents AC / DC\nModel: ASITA DURA PA610\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\nDCI \n\n\n\nRange\n60.00 A\n6.00 A\, 54.00 A\n\n\n\n\n\n600.00 A\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A\n100 A\, 900 A\n\n\n\n\n\n\nACI \n\n\n\nRange\n60.00 A 50 Hz\n6.00 A\, 54.00 A\n\n\n\n\n\n60.00 A 100 Hz\n6.00 A\n\n\n\n60.00 A 400 Hz\n6.00 A\n\n\n\n600.0 A 50 Hz\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A 50 Hz\n100 A\, 900 A\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nRange\n1 A < I ≤ 10 A\nda 1.4 x 10^-5 x I a 1.7 x 10^-5 x I\n\n\n\n\n\n10 A < I ≤ 100 A\nda 1.7 x 10^-5 x I a 4.8 x 10^-5 x I\n\n\n\n100 A < I ≤ 300 A\n1.2 x 10^-4 x I\n\n\n\n300 A < I ≤ 1750 A\n4.4 x 10^-4 x I\n\n\n\n\n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n3 A < I ≤ 20 A\n40 Hz ≤f ≤10 kHz\n2.0 x 10^-4 x I\n\n\n\n 100 A < I ≤ 240 A\n40 Hz ≤f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n240 A < I ≤ 1000 A\n40 Hz ≤f ≤ 60 Hz\n1.0 x 10^-3 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment:bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cch_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCH.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211208T093610Z
LAST-MODIFIED:20261009T091237Z
UID:651-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_03_N_AG
DESCRIPTION:N type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: N type thermocouple with digital readout thermometer\nModel / type: Beamex MC2-TE + N type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.25 °C\n\n\n400 °C\n0.25 °C\n\n\n500 °C\n0.27 °C\n\n\n600 °C\n0.27 °C\n\n\n700 °C\n 1.1 °C\n\n\n800 °C\n 1.1 °C\n\n\n900 °C\n 1.1 °C\n\n\n1000 °C\n 1.1 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_n-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_03_N_AG-e1788343344137.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20211208T161357Z
LAST-MODIFIED:20261009T091144Z
UID:663-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_07_AG
DESCRIPTION:In air temperature meter calibration \nEPTIS ID: 707603\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermo hygrometer\nModel / type: Rotronic HygroPalm 32 + Rotronic HC2A-S\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60) °C \nReference Laboratory CMC:\n0.15 °C \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_07-eptis-id-707603/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/1648621320179-scaled-e1788343206379.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T145941
CREATED:20231228T154820Z
LAST-MODIFIED:20261119T105044Z
UID:2124-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043T_01_N_AG
DESCRIPTION:N type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: N type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.23 °C\n\n\n400 °C\n0.24 °C\n\n\n500 °C\n0.26 °C\n\n\n600 °C\n0.26 °C\n\n\n700 °C\n 1.1 °C\n\n\n800 °C\n 1.1 °C\n\n\n900 °C\n 1.1 °C\n\n\n1000 °C\n 1.1 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_01_n_ag/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/Termocoppia-N-Nicrobel-scaled-e1788342892949.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20211129T115019Z
LAST-MODIFIED:20261009T091024Z
UID:523-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_AG
DESCRIPTION:6½ digit DMM DC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM DC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n100 mV\n0.0013 % rdg + 0.98 µV\n(-90\, 0\, 10\, 90) mV\n\n\n1 V\n0.0013 % rdg + 2.0 µV\n(-0.9\, 0.1\, 0.9) V\n\n\n10 V\n0.00092 % rdg + 12 µV\n(-9\, -5\, -1\, 1\, 3\, 5\, 7\, 9) V\n\n\n100 V\n0.0012 % rdg + 0.18 mV\n(-90\, 10\, 90) V\n\n\n1000 V\n0.00034 % rdg + 14 mV\n(-900\, 100\, 900) V\n\n\nIN DCI RANGE\n\n\n\n\n100 µA\n0.0065% rdg + 0.19 µA\n(0\, 10\, 90) µA\n\n\n1 mA\n0.011% rdg + 2.2 µA\n(0.1\, 0.9) mA\n\n\n10 mA\n0.019% rdg + 50 µA\n(1\, 9) mA\n\n\n100 mA\n0.019% rdg + 50 µA\n(-90\, 10\, 90) mA\n\n\n1 A\n0.019% rdg + 50 µA\n(0.1\, 0.9) A\n\n\n10 A\n0.019% rdg + 50 µA\n(1 A\, 9) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.0075 % rdg + 15 µΩ\n(0\, 1\, 10) Ω\n\n\n100 Ω\n0.0021 % rdg + 45 µΩ\n(10\, 100) Ω\n\n\n1 kΩ\n0.0020 % rdg + 0.67 mΩ\n(0.1\, 1.0) kΩ\n\n\n10 kΩ\n0.0020 % rdg + 5.6 mΩ\n(1\, 10) kΩ\n\n\n100 kΩ\n0.0022 % rdg + 0.38 Ω\n(10\, 100) kΩ\n\n\n1 MΩ\n0.0034 % rdg + 0.45 Ω\n(0.1\, 1.0) MΩ\n\n\n10 MΩ\n0.0053 % rdg + 0.19 kΩ\n(1\, 10) MΩ\n\n\n100 MΩ\n0.035 % rdg + 20 kΩ\n(10\, 100) MΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_01_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20211129T115317Z
LAST-MODIFIED:20261009T090952Z
UID:525-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_03_AG
DESCRIPTION:6½ digit DMM\, AC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM AC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 900 V from 50 Hz up to 100 kHz\n\n\n\n\n100 mV\n\n\n\n\n1 kHz\n0.034% rdg + 18 µV\n(10\, 90) mV\n\n\n50 Hz\n0.034% rdg + 18 µV\n90 mV\n\n\n20 kHz\n0.046% rdg + 27 µV\n90 mV\n\n\n(50\, 100) kHz\n0.18% rdg + 46 µV\n90 mV\n\n\n1 V\n\n\n\n\n(0.05\, 1) kHz\n0.029% rdg + 0.11 mV\n0.9 V\n\n\n20 kHz\n0.030% rdg + 0.11 mV\n0.9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 0.41 mV\n0.9 V\n\n\n10 V\n\n\n\n\n1 kHz\n0.029% rdg + 1.1 mV\n(1\, 5\, 9) V\n\n\n(0.05\, 20) kHz\n0.029% rdg + 1.1 mV\n9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 4.1 mV\n9 V\n\n\n100 V\n\n\n\n\n(0.05\, 1\, 20) kHz\n0.025% rdg + 11 mV\n90 V\n\n\n(50\, 100) kHz\n0.11% rdg + 41 mV\n90 V\n\n\n1000 V\n\n\n\n\n50 Hz\n0.037% rdg + 0.16 V\n900 V\n\n\n(5\, 10) kHz\n0.035% rdg + 0.25 V\n900 V\n\n\nACI up to 9 A from 20 Hz up to 5 kHz\n\n\n\n\n100 µA\n\n\n\n\n(0.05\, 1) kHz\n0.041 % rdg + 33 nA\n(10\, 90) µA\n\n\n5 kHz\n0.041 % rdg + 33 nA\n90 µA\n\n\n1 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 0.24 µA\n0.9 mA\n\n\n10 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 2.7 µA\n9 mA\n\n\n100 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 27 µA\n90 mA\n\n\n1 A\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.17 % rdg + 0.84 mA\n0.9 A\n\n\n10 A\n\n\n\n\n(0.05\, 1) kHz\n0.36 % rdg + 15 mA\n9 A\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_03_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20211207T100657Z
LAST-MODIFIED:20261009T090725Z
UID:629-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043T_01_S_AG
DESCRIPTION:S type thermocouple calibration \nEPTIS ID: 797767\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: thermocouple\nModel / type: S type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n300 °C\n0.19 °C\n\n\n400 °C\n0.19 °C\n\n\n500 °C\n0.22 °C\n\n\n600 °C\n0.22 °C\n\n\n700 °C\n0.51 °C\n\n\n800 °C\n0.51 °C\n\n\n900 °C\n0.51 °C\n\n\n1000 °C\n0.51 °C\n\n\n1080 °C\n0.51 °C\n\n\n1200 °C\n1.2 °C\n\n\n1300 °C\n1.2 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797767/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/ILC-TC-S.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20250105T111709Z
LAST-MODIFIED:20261009T090656Z
UID:2957-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_02_AG
DESCRIPTION:5½ digit multifunction calibrator DC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator DC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n10 mV\n0.0011 % rdg + 0.49 µV\n(-10\, -1\, 1\, 10) mV\n\n\n100 mV\n0.0011 % rdg + 0.49 µV\n(-100\, -10\, 10\, 100) mV\n\n\n1 V\n0.00083 % rdg + 1.8 µV\n(-1.0\, -0.1\, 0.1\, 0.2\, 0.3\, 0.4\, 0.5\, 0.6\, 0.7\, 0.8\, 0.9\, 1.0) V\n\n\n10 V\n0.00072 % rdg + 6.3 µV\n(-10\, -1\, 1\, 10) V\n\n\n100 V\n0.00083 % rdg + 0.12 mV\n(-100\, -10\, 10\, 100) V\n\n\n1000 V\n0.0011 % rdg + 2.1 mV\n(-1000\, -100\, 100\, 1000) V\n\n\nIN DCI RANGE\n\n\n\n\n200 µA\n0.0051 % rdg + 1.3 nA up to 100 µA \n0.0051 % rdg + 7.9 nA above 100 µA\n(-200\, -20\, 20\, 200) µA\n\n\n2 mA\n0.0051 % rdg + 7.9 nA up to 1 mA \n0.0051 % rdg + 79 nA above 1 mA\n(-2.0\, -0.2\, 0.2\, 2.0) mA\n\n\n20 mA\n0.0051 % rdg + 79 nA up to 10 mA \n0.011 % rdg + 1.3 µA above 10 mA\n(-20\, -2. 2\, 20) mA\n\n\n200 mA\n0.011 % rdg + 1.3 µA up to 100 mA \n0.016 % rdg + 24 µA above 100 mA\n(-200\, -20\, 20\, 200) mA\n\n\n2 A\n0.016 % rdg + 24 µA up to 1 A \n0.0041 % rdg + 0.11 mA above 1 A\n(-2.0\, -0.2\, 0.2\, 2.0) A\n\n\n20 A\n0.0041 % rdg + 0.11 mA\n(-20\, -2\, 2\, 20) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.011 % rdg + 0.11 mΩ\n10 Ω\n\n\n100 Ω\n0.0029 % rdg + 0.42 mΩ\n100 Ω\n\n\n1.0 kΩ\n0.0026 % rdg + 4.2 mΩ\n1.0 kΩ\n\n\n10 kΩ\n0.0026 % rdg + 42 mΩ\n10 kΩ\n\n\n100 kΩ\n0.0026 % rdg + 0.42 Ω\n100 kΩ\n\n\n1 MΩ\n0.0036 % rdg + 5.4 Ω\n1.0 MΩ\n\n\n10 MΩ\n0.021 % rdg + 0.23 kΩ\n10 MΩ\n\n\n100 MΩ\n0.073 % rdg + 15 kΩ\n100 MΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_02_ag/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20250105T115704Z
LAST-MODIFIED:20261009T090514Z
UID:2962-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_04_AG
DESCRIPTION:5½ digit multifunction calibrator\, AC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator AC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 1000 V from 40 Hz up to 10 kHz\n\n\n\n\n10 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n10 mV\n\n\n100 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n100 mV\n\n\n1 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 17 µV\n 1 V\n\n\n10 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 0.17 mV\n10 V\n\n\n100 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.009 7 % rdg + 1.4 mV\n100 V\n\n\n1000 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.012 % rdg + 12 mV\n1000 V\n\n\nACI up to 20 A from 20 Hz up to 1 kHz\n\n\n\n\n200 µA\n\n\n\n\n(0.02\, 0.20\, 1.00) kHz\n0.017 % rdg + 0.20 µA\n200 µA\n\n\n2 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 2.0 µA\n2 mA\n\n\n20 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 20 µA\n20 mA\n\n\n200 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.10 % rdg + 0.70 mA\n200 mA\n\n\n2 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.003 4 % rdg + 1.5 mA\n2 A\n\n\n20 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.005 0 % rdg + 3.7 mA\n20 A\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_04_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2025/01/Meatest-M143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T145941
CREATED:20260116T181831Z
LAST-MODIFIED:20261119T104248Z
UID:3784-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_10E-6O_EX
DESCRIPTION:Micro-ohmmeter Resistance calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: micro ohmmeter\nModel: Valhalla Scientific 4300B\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\n RANGE\nCMC\nMeasurement Points\n\n\n\n\n2.0000 mΩ (test current 10 A)\n20 ppm RDG\n(0.0000\, 1.0000) mΩ\n\n\n20.000 mΩ (test current 10 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n20.000 mΩ (test current 1 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n200.00 mΩ (test current 1 A)\n5 ppm RDG\n(0.00\, 100.00) mΩ\n\n\n200.00 mΩ (test current 0.1 A)\n5 ppm RDG\n(0.000\, 100.00) mΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_10e-6o_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2026/01/Valhalla-4300B.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20261122T145941
CREATED:20211205T111916Z
LAST-MODIFIED:20261009T090344Z
UID:599-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043E_05_AG
DESCRIPTION:Temperature calibrator calibration \nEPTIS ID: 703492\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: temperature calibrator\nModel / type: Beamex MC5\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type S\n0.11 – 0.0022 % rdg °C with 0° C RJ\n0.17 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Simulation use with Thermocouple Type S\n0.032 °C + 0.0012 % rdg with 0° C RJ\n0.14 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type T\n0.029 °C – 0.0033 % rdg with 0° C RJ\n0.13 °C – 0.0083 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Simulation use with Thermocouple Type T\n0.015 °C with 0° C RJ\n0.13 °C – 0.0067 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with RTD\n0.0020 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\nTemperature Simulation use with RTD\n0.0019 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_05_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Beamex-MC5.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20261122T145941
CREATED:20211208T095445Z
LAST-MODIFIED:20261009T090256Z
UID:654-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_02_AG
DESCRIPTION:IPRT Calibration \nEPTIS ID: 708010\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires IPRT\nModel / type: Klasmeier eXacal Pt100 IH\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.085 °C\n\n\n-80 °C\n0.017 °C\n\n\n-60 °C\n0.017 °C\n\n\n-40 °C\n0.017 °C\n\n\n-20 °C\n0.017 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.031 °C\n\n\n100 °C\n0.028 °C\n\n\n150 °C\n0.028 °C\n\n\n200 °C\n0.028 °C\n\n\n250 °C\n0.028 °C\n\n\n300 °C\n0.028 °C\n\n\n400 °C\n0.072 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-708010/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_02_AG-e1788342730139.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20261122T145941
CREATED:20211208T152820Z
LAST-MODIFIED:20261009T090225Z
UID:659-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043T_03_PT_AG
DESCRIPTION:IPRT with a Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: IPRT with a Digital Readout Thermometer calibration\nModel: Fluke 1502A + Fluke 5609\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.086 °C\n\n\n-80 °C\n0.019 °C\n\n\n-60 °C\n0.019 °C\n\n\n-40 °C\n0.019 °C\n\n\n-20 °C\n0.019 °C\n\n\n0.01 °C\n0.005 °C\n\n\n50 °C\n0.019 °C\n\n\n100 °C\n0.029 °C\n\n\n150 °C\n0.029 °C\n\n\n200 °C\n0.029 °C\n\n\n250 °C\n0.029 °C\n\n\n300 °C\n0.029 °C\n\n\n400 °C\n0.073 °C\n\n\n500 °C\n0.14 °C\n\n\n600 °C\n0.14 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/1502A-SPRT-scaled-e1788342253645.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20261122T145941
CREATED:20211129T143141Z
LAST-MODIFIED:20261009T090115Z
UID:543-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_01_T_AG
DESCRIPTION:T type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.14 °C\n\n\n-80 °C\n0.14 °C\n\n\n-60 °C\n0.14 °C\n\n\n-40 °C\n0.14 °C\n\n\n-20 °C\n0.14 °C\n\n\n0 °C\n0.069 °C\n\n\n50 °C\n0.069 °C\n\n\n100 °C\n0.14 °C\n\n\n150 °C\n0.14 °C\n\n\n200 °C\n0.14 °C\n\n\n250 °C\n0.14 °C\n\n\n300 °C\n0.14 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797772/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/17043T_01_T_AG-e1788341313143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20261122T145941
CREATED:20211207T102108Z
LAST-MODIFIED:20261009T090042Z
UID:633-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043T_03_T_AG
DESCRIPTION:T type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: digital readout with thermocouple\nModel / type: digital readout Beamex MC2-TE + T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-100 °C\n0.16 °C\n\n\n-80 °C\n0.16 °C\n\n\n-60 °C\n0.16 °C\n\n\n-40 °C\n0.16 °C\n\n\n-20 °C\n0.16 °C\n\n\n0 °C\n0.075 °C\n\n\n50 °C\n0.075 °C\n\n\n100 °C\n0.17 °C\n\n\n150 °C\n0.17 °C\n\n\n200 °C\n0.17 °C\n\n\n250 °C\n 0.17 °C\n\n\n300 °C\n 0.17 °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_t-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/17043T_03_T_AG-e1788341141821.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20261122T145941
CREATED:20260118T082742Z
LAST-MODIFIED:20261119T115224Z
UID:3807-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043E_01_03_HVP_EX
DESCRIPTION:High voltage meter with probe calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: high voltage meter + probe\nModel: Vitrek 4700 + Vitrek HVL-70\nExternal provider for the calibration of the PT item:  an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nDCV RANGE\n\n\n\n\n1600.00 V\n0.01 % rdg\n1000.00 V\n\n\n16000.0 V\n0.01 % rdg\n(-10000.0\, 10000.0) V\n\n\n70000 V\n0.01 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\nACV RANGE 50 Hz\n\n\n\n\n1600.00 V\n0.05 % rdg\n1000.00 V\n\n\n 16000.0 V\n0.05 % rdg\n10000.0 V\n\n\n70000 V\n0.05 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: even-numbered years in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_hvp_ex/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T145941
CREATED:20211209T162423Z
LAST-MODIFIED:20261009T103506Z
UID:671-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_01_EX
DESCRIPTION:Impedance\, differential time and tripping current test\, earth resistance meter calibration \nEPTIS ID: 882562\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: multifunctional measuring instrument\nModel / type: Metrel MI 3100 SE\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nImpedance measurement \n1. Z LINE: line impedance phase-neutral / phase (METREL MI 3100 s)\n2. Z LOOP: impedance of the fault loop phase / earth (METREL MI 3100 s)\n3. Zs rcd: impedance of the fault loop with low test current (METREL MI 3100 s) \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\n UUT setting\nNominal measurement points\n\n\n\n\nZ line\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZ loop\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZs rcd\n(0.50\, 1.80\, 5.00) Ω\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.50 Ω\n8 mΩ\n\n\n1.80 Ω\n18 mΩ\n\n\n5.00 Ω\n30 mΩ\n\n\n50.0 Ω\n0.39 Ω\n\n\n100.0 Ω\n0.50 Ω\n\n\n180 Ω\n1.0 Ω\n\n\n\n\nDifferential tripping time (RCD t) and current (RCD I) \nMeasurement points:\nTrip Out time (RCD t) \n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA X1 – AC – 0°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n300 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n30 mA X1 – AC – 180°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- Selective\n390 ms\n\n\n30 mA X2 – AC – 0°- general non delayed\n150 ms\n\n\n30 mA X5 – AC – 0°- general non delayed\n40 ms\n\n\n500 mA X5 – AC – 0°- general non delayed\n20 ms\n\n\n\nTrip Out current (RCD I)\nExecution of the points in the table to 20 ms (Trip out time reference) \n\n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA – AC – 0° – general non delayed\n10 mA\n\n\n30 mA – AC – 0° – general non delayed\n30 mA\n\n\n1000 mA – AC – 0° – general non delayed\n1000 mA\n\n\n30 mA – AC – 180° – general non delayed\n30 mA\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\nRCD trip Time\n0.020 % rdg + 0.25 ms\n\n\nRCD trip Current\n1.0 % rdg\n\n\n\n\nMeasurement of earth resistance value \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.10 Ω\n5.0 mΩ\n\n\n1.0 Ω\n10 mΩ\n\n\n10 Ω\n60 mΩ\n\n\n100 Ω\n0.50 Ω\n\n\n900 Ω\n5.0 Ω\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_01_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Metrel-MI3100-s.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T145941
CREATED:20211209T171746Z
LAST-MODIFIED:20261009T103556Z
UID:676-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_02_EX
DESCRIPTION:Fault loop impedance with high current meter \nEPTIS ID: 882556\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: Loop impedance meter\nModel / type: Thytronic Impmeter2\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n80 mΩ\n3.0 mΩ\n\n\n100 mΩ\n3.0 mΩ\n\n\n130 mΩ\n3.0 mΩ\n\n\n0.20 Ω\n15 mΩ\n\n\n 0.90 Ω\n19 mΩ\n\n\n5.0 Ω\n44 mΩ\n\n\n9.0 Ω\n68 mΩ\n\n\n19 Ω\n0.13 Ω\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_02_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/Thytronic-Impmeter2.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T145941
CREATED:20211210T180945Z
LAST-MODIFIED:20261009T103644Z
UID:678-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_03_EX
DESCRIPTION:DCV\, ACV dielectric strength test meter  \nEPTIS ID: 882638\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: AC/DC/IR Hipot tester\nModel: Quadtech Sentry 30 Plus\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory pr NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement points\n\nCMC\n\n\n\n\nDielectric strength DCV\n (1000\, 3000\, 5000) V\n0.30 % rdg + 5 V\n\n\nDielectric strength ACV 50 Hz\n (1000\, 3000\, 5000) V\n0.50 % rdg + 5 V\n\n\n\n\n\n\n\n\n\nMeasurement points\n\n\nCMC\n\n\n\n\nDielectric strength DCV\n1000 V\n2000 V\n5000 V\n1 mA\n4 mA\n1 mA\n0.20 % rdg\n\n\nDielectric strength ACV\n1000 V\n2000 V\n5000 V\n1 mA\n14 mA\n15 mA\n0.20 % rdg\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_03_ex/
CATEGORIES:ILC - Electrical safety
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T145941
CREATED:20211210T182113Z
LAST-MODIFIED:20261009T103753Z
UID:680-1820188800-1820275199@www.agmetrology.com
SUMMARY:17043S_04_EX
DESCRIPTION:Leakage current\, earth bond resistance meter \nEPTIS ID: 882600\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: PAT tester\nModel: Metrel MI2142 AlphaPAT\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\nDifferential leakage\n(2\, 5\, 10\, 15) mA\n0.3 % rdg + 2.0 µA\n\n\nTouch leakage\n(1.0\, 1.5) mA\n0.3 % rdg + 2.0 µA\n\n\n Earth bond resistance\n 500 mΩ\n 8.0 mΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_04_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/AlphaPAT.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270906
DTEND;VALUE=DATE:20270907
DTSTAMP:20261122T145941
CREATED:20220525T095151Z
LAST-MODIFIED:20261009T100641Z
UID:1054-1820188800-1820275199@www.agmetrology.com
SUMMARY:PT 17043O_01 – EPTIS ID XXXXX
DESCRIPTION:Illuminance up to 400000 lx   \nItem: light meter\nModel: HT Instruments – HT 309\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\nup to 400000 lx\nReference Laboratory CMC:\nto be defined \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: September 2023 \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/pt-17043o_01-eptis-id-xxxxx/
CATEGORIES:ILC- Optical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/1_luxmetro.jpg