BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260909T130348
CREATED:20211210T182810Z
LAST-MODIFIED:20260421T074125Z
UID:667-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043T_02_EX
DESCRIPTION:SPRT calibration \nEPTIS ID: 848623\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires resistance thermometer\nModel / type: Rosemount 162CE\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points e Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.005 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-848623/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/SPRT.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260909T130348
CREATED:20231228T160035Z
LAST-MODIFIED:20260421T074104Z
UID:2126-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043T_03_PT_EX
DESCRIPTION:SPRT with Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / Item: SPRT with a Digital Readout Thermometer calibration\nModel / type: Fluke 1522 + Fluke 5609-400-G\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points e Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.004 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043t_03_pt_ex-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/catena-e1703780406498.jpeg
END:VEVENT
END:VCALENDAR