BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261022T230138
CREATED:20211204T172346Z
LAST-MODIFIED:20261009T095437Z
UID:572-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_35MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 35 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 3.5\, 7.0\, 10.5\, 14.0\, 17.5\, 21.0\, 24.5\, 28.0\, 31.5\, 35.0) MPa \nReference Laboratory Measurement:\n0.0076 % rdg + 2.0 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_35mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261022T230138
CREATED:20241102T102317Z
LAST-MODIFIED:20261009T095540Z
UID:2624-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_100MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 100 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific DigiQuartz 735 + Paroscientific DigiQuartz 415K-101\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60\, 70\, 80\, 90\, 100) MPa \nReference Laboratory Measurement:\n0.0055 % rdg + 2.2 Pa (up to 6 MPa)\n0.0076 % rdg + 2.0 Pa (range 6 MPa to 120 MPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_100mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-415K-101.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261022T230138
CREATED:20241102T103452Z
LAST-MODIFIED:20261001T092805Z
UID:2629-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_280MR_EX
DESCRIPTION:Hydraulic pressure transducer up to 280 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM4 A280Ms-L\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\n(0\, 28\, 56\, 84\, 112\, 140\, 168\, 196\, 224\, 252\, 280) MPa \nCMC from the calibration laboratory’s accreditation schedule:\n0.0051 % rdg + 2.7 kPa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_280mr_ex/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20211129T115504Z
LAST-MODIFIED:20261009T092814Z
UID:528-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_-95_100_kR_AG
DESCRIPTION:Pneumatic pressure transducer from -95 kPa to 100 kPa calibration\, gauge pressure \nEPTIS ID: 806743\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: GE Druck DPI150\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-95\, -80\, -60\, -40\, -20\, 0\, 20\, 40\, 60\, 80\, 100) kPa \nReference Laboratory CMC:\n|0.0019 %| rdg + 0.12 Pa (range -95 kPa to 0 kPa)\n0.0019 % rdg + 0.06 Pa (range 0 kPa to 100 kPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_-95kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/Gemini_Generated_Image_rmst6qrmst6qrmst.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20211129T143255Z
LAST-MODIFIED:20261009T092648Z
UID:545-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_7MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 7 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.0\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.40 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T083030Z
LAST-MODIFIED:20261009T093036Z
UID:2586-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_-25_25kR_AG
DESCRIPTION:Pneumatic pressure transducer from -25 kPa to 25 kPa calibration\, gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0004\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-25\, -20\, -15\, -10\, 0\, 5\, 10\, 15\, 20\, 25) kPa \nReference Laboratory CMC:\n|0.0019 %| rdg + 0.12 Pa (range -25 kPa to 0 kPa)\n0.0019 % rdg + 0.06 Pa (range 0 kPa to 25 kPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_25kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0004.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T084057Z
LAST-MODIFIED:20261009T094717Z
UID:2589-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_170kA_AG
DESCRIPTION:Pneumatic pressure transducer from 1.4 kPa to 170 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: Paroscientific 745\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(1.4\, 17.0\, 34.0\, 51.0\, 68.0\, 85.0\, 102.0\, 119.0\, 136.0\, 153.0\, 170.0) kPa \nReference Laboratory CMC:\n0.0019 % rdg + 0.29 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_170ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T092403Z
LAST-MODIFIED:20261009T094406Z
UID:2597-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_350kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 350 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DHI RPM1-G0100-R\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 35\, 70\, 105\, 140\, 175\, 210\, 245\, 280\, 315\, 350) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_350kr_ag/
CATEGORIES:ILC - Pressure
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T092926Z
LAST-MODIFIED:20261009T093338Z
UID:2601-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 700 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0100\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0016 % rdg + 0.04 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0100.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T093904Z
LAST-MODIFIED:20261009T095023Z
UID:2603-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_700kA_AG
DESCRIPTION:Pneumatic pressure transducer from 12 kPa to 700 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: ‘Paroscientific Digiquartz 715 + Paroscientific Digiquartz 6000-100A\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(12\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0017 % rdg + 0.31 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-715-6000-100A.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T094759Z
LAST-MODIFIED:20261009T093433Z
UID:2606-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 3.5 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: CalRef Cube-P\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.40 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Cube-P.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T095222Z
LAST-MODIFIED:20261009T095157Z
UID:2608-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_3.5MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.17 MPa to 3.5 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 A0500\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.17\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-A0500.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T095819Z
LAST-MODIFIED:20261009T095255Z
UID:2611-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_7MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.2 MPa to 7 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.2\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.54 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20271004
DTEND;VALUE=DATE:20271005
DTSTAMP:20261022T230138
CREATED:20241102T100749Z
LAST-MODIFIED:20261009T094525Z
UID:2617-1822608000-1822694399@www.agmetrology.com
SUMMARY:17043P_03_20MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 20 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific 745-3K\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 2\, 4\, 6\, 8\, 10\, 12\, 14\, 16\, 18\, 20) MPa \nReference Laboratory CMC: \n0.005 5 % rdg + 1.8 kPa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_20mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
END:VCALENDAR