BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261023T010306
CREATED:20211204T172346Z
LAST-MODIFIED:20261009T095437Z
UID:572-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_35MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 35 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 3.5\, 7.0\, 10.5\, 14.0\, 17.5\, 21.0\, 24.5\, 28.0\, 31.5\, 35.0) MPa \nReference Laboratory Measurement:\n0.0076 % rdg + 2.0 Pa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_35mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261023T010306
CREATED:20241102T102317Z
LAST-MODIFIED:20261009T095540Z
UID:2624-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_100MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 100 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific DigiQuartz 735 + Paroscientific DigiQuartz 415K-101\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60\, 70\, 80\, 90\, 100) MPa \nReference Laboratory Measurement:\n0.0055 % rdg + 2.2 Pa (up to 6 MPa)\n0.0076 % rdg + 2.0 Pa (range 6 MPa to 120 MPa) \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_100mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-415K-101.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20261023T010306
CREATED:20241102T103452Z
LAST-MODIFIED:20261001T092805Z
UID:2629-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_280MR_EX
DESCRIPTION:Hydraulic pressure transducer up to 280 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM4 A280Ms-L\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\n(0\, 28\, 56\, 84\, 112\, 140\, 168\, 196\, 224\, 252\, 280) MPa \nCMC from the calibration laboratory’s accreditation schedule:\n0.0051 % rdg + 2.7 kPa \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_280mr_ex/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
END:VCALENDAR