BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:AG Metrology
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T133101
CREATED:20211205T165512Z
LAST-MODIFIED:20261001T093348Z
UID:605-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCL_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nEPTIS ID: 882510\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp with display for low currents AC / DC\nModel: UNI-T UT211B\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value\nMeasurement points: \nDCI \nRange 6000 mA ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nACI \nRange 600.0 mA 50 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 100 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 400 Hz ⇒ (60.0\, 540.0) mA\n6000 mA 50 Hz ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nCMC from the calibration laboratory’s accreditation schedule:\nRange 1 µA < I ≤ 1 A ⇒ da 2.5 x 10-5 x I a 1.4 x 10-5 x I\n1 A < I ≤ 10 A ⇒ da 1.4 x 10-5 x I a 1.7 x 10-5 x I \nRange 2.5 mA < I ≤ 3 A 40 Hz ≤ f ≤ 10 kHz ⇒ 1.3 X 10-4 X I\n50 mA < I ≤ 100 A 40 Hz ≤ f ≤ 60 Hz ⇒ 1.3 X 10-4 X I \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_ccl_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCL-1.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T133101
CREATED:20211205T171248Z
LAST-MODIFIED:20261001T093321Z
UID:609-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCT_EX
DESCRIPTION:Current clamp transducer AC  calibration \nEPTIS ID: 882534\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp transducer AC\nModel: Hioki CT9667-02\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\nRange 500 A (1mV AC / A) 50 Hz    ⇒     (50\, 450) A\nRange 5000 A (0.1 mV AC / A) 50 Hz     ⇒     (500\, 1500\, 2500\, 3500\, 4500) A \nCMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤ f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n  100 A < I ≤ 240 A\n40 Hz ≤ f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n 240 A < I ≤ 10 kA\n40 Hz ≤ f ≤ 60 Hz\n1.0 x 10^-4 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cct_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCT-HIOKI.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T133101
CREATED:20211205T173620Z
LAST-MODIFIED:20261001T093257Z
UID:614-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCH_EX
DESCRIPTION:Current clamp with display for high currents AC / DC \nEPTIS ID: 882516\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: Current clamp with display for high currents AC / DC\nModel: ASITA DURA PA610\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\nDCI \n\n\n\nRange\n60.00 A\n6.00 A\, 54.00 A\n\n\n\n\n\n600.00 A\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A\n100 A\, 900 A\n\n\n\n\n\n\nACI \n\n\n\nRange\n60.00 A 50 Hz\n6.00 A\, 54.00 A\n\n\n\n\n\n60.00 A 100 Hz\n6.00 A\n\n\n\n60.00 A 400 Hz\n6.00 A\n\n\n\n600.0 A 50 Hz\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A 50 Hz\n100 A\, 900 A\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nRange\n1 A < I ≤ 10 A\nda 1.4 x 10^-5 x I a 1.7 x 10^-5 x I\n\n\n\n\n\n10 A < I ≤ 100 A\nda 1.7 x 10^-5 x I a 4.8 x 10^-5 x I\n\n\n\n100 A < I ≤ 300 A\n1.2 x 10^-4 x I\n\n\n\n300 A < I ≤ 1750 A\n4.4 x 10^-4 x I\n\n\n\n\n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n3 A < I ≤ 20 A\n40 Hz ≤f ≤10 kHz\n2.0 x 10^-4 x I\n\n\n\n 100 A < I ≤ 240 A\n40 Hz ≤f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n240 A < I ≤ 1000 A\n40 Hz ≤f ≤ 60 Hz\n1.0 x 10^-3 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment:bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cch_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCH.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T133101
CREATED:20211129T115019Z
LAST-MODIFIED:20261009T091024Z
UID:523-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_AG
DESCRIPTION:6½ digit DMM DC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM DC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n100 mV\n0.0013 % rdg + 0.98 µV\n(-90\, 0\, 10\, 90) mV\n\n\n1 V\n0.0013 % rdg + 2.0 µV\n(-0.9\, 0.1\, 0.9) V\n\n\n10 V\n0.00092 % rdg + 12 µV\n(-9\, -5\, -1\, 1\, 3\, 5\, 7\, 9) V\n\n\n100 V\n0.0012 % rdg + 0.18 mV\n(-90\, 10\, 90) V\n\n\n1000 V\n0.00034 % rdg + 14 mV\n(-900\, 100\, 900) V\n\n\nIN DCI RANGE\n\n\n\n\n100 µA\n0.0065% rdg + 0.19 µA\n(0\, 10\, 90) µA\n\n\n1 mA\n0.011% rdg + 2.2 µA\n(0.1\, 0.9) mA\n\n\n10 mA\n0.019% rdg + 50 µA\n(1\, 9) mA\n\n\n100 mA\n0.019% rdg + 50 µA\n(-90\, 10\, 90) mA\n\n\n1 A\n0.019% rdg + 50 µA\n(0.1\, 0.9) A\n\n\n10 A\n0.019% rdg + 50 µA\n(1 A\, 9) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.0075 % rdg + 15 µΩ\n(0\, 1\, 10) Ω\n\n\n100 Ω\n0.0021 % rdg + 45 µΩ\n(10\, 100) Ω\n\n\n1 kΩ\n0.0020 % rdg + 0.67 mΩ\n(0.1\, 1.0) kΩ\n\n\n10 kΩ\n0.0020 % rdg + 5.6 mΩ\n(1\, 10) kΩ\n\n\n100 kΩ\n0.0022 % rdg + 0.38 Ω\n(10\, 100) kΩ\n\n\n1 MΩ\n0.0034 % rdg + 0.45 Ω\n(0.1\, 1.0) MΩ\n\n\n10 MΩ\n0.0053 % rdg + 0.19 kΩ\n(1\, 10) MΩ\n\n\n100 MΩ\n0.035 % rdg + 20 kΩ\n(10\, 100) MΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_01_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T133101
CREATED:20211129T115317Z
LAST-MODIFIED:20261009T090952Z
UID:525-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_03_AG
DESCRIPTION:6½ digit DMM\, AC calibration \nEPTIS ID: 699139\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 6½ digit DMM AC\nModel: Fluke 8846A\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 900 V from 50 Hz up to 100 kHz\n\n\n\n\n100 mV\n\n\n\n\n1 kHz\n0.034% rdg + 18 µV\n(10\, 90) mV\n\n\n50 Hz\n0.034% rdg + 18 µV\n90 mV\n\n\n20 kHz\n0.046% rdg + 27 µV\n90 mV\n\n\n(50\, 100) kHz\n0.18% rdg + 46 µV\n90 mV\n\n\n1 V\n\n\n\n\n(0.05\, 1) kHz\n0.029% rdg + 0.11 mV\n0.9 V\n\n\n20 kHz\n0.030% rdg + 0.11 mV\n0.9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 0.41 mV\n0.9 V\n\n\n10 V\n\n\n\n\n1 kHz\n0.029% rdg + 1.1 mV\n(1\, 5\, 9) V\n\n\n(0.05\, 20) kHz\n0.029% rdg + 1.1 mV\n9 V\n\n\n(50\, 100) kHz\n0.12% rdg + 4.1 mV\n9 V\n\n\n100 V\n\n\n\n\n(0.05\, 1\, 20) kHz\n0.025% rdg + 11 mV\n90 V\n\n\n(50\, 100) kHz\n0.11% rdg + 41 mV\n90 V\n\n\n1000 V\n\n\n\n\n50 Hz\n0.037% rdg + 0.16 V\n900 V\n\n\n(5\, 10) kHz\n0.035% rdg + 0.25 V\n900 V\n\n\nACI up to 9 A from 20 Hz up to 5 kHz\n\n\n\n\n100 µA\n\n\n\n\n(0.05\, 1) kHz\n0.041 % rdg + 33 nA\n(10\, 90) µA\n\n\n5 kHz\n0.041 % rdg + 33 nA\n90 µA\n\n\n1 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 0.24 µA\n0.9 mA\n\n\n10 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 2.7 µA\n9 mA\n\n\n100 mA\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.048 % rdg + 27 µA\n90 mA\n\n\n1 A\n\n\n\n\n(0.05\, 1\, 5) kHz\n0.17 % rdg + 0.84 mA\n0.9 A\n\n\n10 A\n\n\n\n\n(0.05\, 1) kHz\n0.36 % rdg + 15 mA\n9 A\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_03_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/11/Tektronix-DMM400-e1746869064412.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T133101
CREATED:20250105T111709Z
LAST-MODIFIED:20261009T090656Z
UID:2957-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_02_AG
DESCRIPTION:5½ digit multifunction calibrator DC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator DC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nIN DCV RANGE\n\n\n\n\n10 mV\n0.0011 % rdg + 0.49 µV\n(-10\, -1\, 1\, 10) mV\n\n\n100 mV\n0.0011 % rdg + 0.49 µV\n(-100\, -10\, 10\, 100) mV\n\n\n1 V\n0.00083 % rdg + 1.8 µV\n(-1.0\, -0.1\, 0.1\, 0.2\, 0.3\, 0.4\, 0.5\, 0.6\, 0.7\, 0.8\, 0.9\, 1.0) V\n\n\n10 V\n0.00072 % rdg + 6.3 µV\n(-10\, -1\, 1\, 10) V\n\n\n100 V\n0.00083 % rdg + 0.12 mV\n(-100\, -10\, 10\, 100) V\n\n\n1000 V\n0.0011 % rdg + 2.1 mV\n(-1000\, -100\, 100\, 1000) V\n\n\nIN DCI RANGE\n\n\n\n\n200 µA\n0.0051 % rdg + 1.3 nA up to 100 µA \n0.0051 % rdg + 7.9 nA above 100 µA\n(-200\, -20\, 20\, 200) µA\n\n\n2 mA\n0.0051 % rdg + 7.9 nA up to 1 mA \n0.0051 % rdg + 79 nA above 1 mA\n(-2.0\, -0.2\, 0.2\, 2.0) mA\n\n\n20 mA\n0.0051 % rdg + 79 nA up to 10 mA \n0.011 % rdg + 1.3 µA above 10 mA\n(-20\, -2. 2\, 20) mA\n\n\n200 mA\n0.011 % rdg + 1.3 µA up to 100 mA \n0.016 % rdg + 24 µA above 100 mA\n(-200\, -20\, 20\, 200) mA\n\n\n2 A\n0.016 % rdg + 24 µA up to 1 A \n0.0041 % rdg + 0.11 mA above 1 A\n(-2.0\, -0.2\, 0.2\, 2.0) A\n\n\n20 A\n0.0041 % rdg + 0.11 mA\n(-20\, -2\, 2\, 20) A\n\n\nIN RESISTANCE RANGE\n\n\n\n\n10 Ω\n0.011 % rdg + 0.11 mΩ\n10 Ω\n\n\n100 Ω\n0.0029 % rdg + 0.42 mΩ\n100 Ω\n\n\n1.0 kΩ\n0.0026 % rdg + 4.2 mΩ\n1.0 kΩ\n\n\n10 kΩ\n0.0026 % rdg + 42 mΩ\n10 kΩ\n\n\n100 kΩ\n0.0026 % rdg + 0.42 Ω\n100 kΩ\n\n\n1 MΩ\n0.0036 % rdg + 5.4 Ω\n1.0 MΩ\n\n\n10 MΩ\n0.021 % rdg + 0.23 kΩ\n10 MΩ\n\n\n100 MΩ\n0.073 % rdg + 15 kΩ\n100 MΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_02_ag/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T133101
CREATED:20250105T115704Z
LAST-MODIFIED:20261009T090514Z
UID:2962-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_04_AG
DESCRIPTION:5½ digit multifunction calibrator\, AC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: 5½ digit multifunction calibrator AC\nModel: Meatest M143\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC \n\n\n\n\n\nType of Test\nCMC\nMeasurement Point\n\n\n\n\nACV up to 1000 V from 40 Hz up to 10 kHz\n\n\n\n\n10 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n10 mV\n\n\n100 mV\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 6 % rdg + 5.5 µV\n100 mV\n\n\n1 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 17 µV\n 1 V\n\n\n10 V\n\n\n\n\n(0.04\, 0.40\, 10.00) kHz\n0.006 8 % rdg + 0.17 mV\n10 V\n\n\n100 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.009 7 % rdg + 1.4 mV\n100 V\n\n\n1000 V\n\n\n\n\n(0.04\, 0.40\, 1.00) kHz\n0.012 % rdg + 12 mV\n1000 V\n\n\nACI up to 20 A from 20 Hz up to 1 kHz\n\n\n\n\n200 µA\n\n\n\n\n(0.02\, 0.20\, 1.00) kHz\n0.017 % rdg + 0.20 µA\n200 µA\n\n\n2 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 2.0 µA\n2 mA\n\n\n20 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.017 % rdg + 20 µA\n20 mA\n\n\n200 mA\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.10 % rdg + 0.70 mA\n200 mA\n\n\n2 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.003 4 % rdg + 1.5 mA\n2 A\n\n\n20 A\n\n\n\n\n(0.05\, 1.00\, 5.00) kHz\n0.005 0 % rdg + 3.7 mA\n20 A\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_04_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2025/01/Meatest-M143.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270503
DTEND;VALUE=DATE:20270504
DTSTAMP:20261122T133101
CREATED:20260116T181831Z
LAST-MODIFIED:20261119T104248Z
UID:3784-1809302400-1809388799@www.agmetrology.com
SUMMARY:17043E_01_10E-6O_EX
DESCRIPTION:Micro-ohmmeter Resistance calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: micro ohmmeter\nModel: Valhalla Scientific 4300B\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\n RANGE\nCMC\nMeasurement Points\n\n\n\n\n2.0000 mΩ (test current 10 A)\n20 ppm RDG\n(0.0000\, 1.0000) mΩ\n\n\n20.000 mΩ (test current 10 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n20.000 mΩ (test current 1 A)\n10 ppm RDG\n(0.000\, 10.000) mΩ\n\n\n200.00 mΩ (test current 1 A)\n5 ppm RDG\n(0.00\, 100.00) mΩ\n\n\n200.00 mΩ (test current 0.1 A)\n5 ppm RDG\n(0.000\, 100.00) mΩ\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in May \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_10e-6o_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2026/01/Valhalla-4300B.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270607
DTEND;VALUE=DATE:20270608
DTSTAMP:20261122T133101
CREATED:20211205T111916Z
LAST-MODIFIED:20261009T090344Z
UID:599-1812326400-1812412799@www.agmetrology.com
SUMMARY:17043E_05_AG
DESCRIPTION:Temperature calibrator calibration \nEPTIS ID: 703492\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: temperature calibrator\nModel / type: Beamex MC5\nReference Laboratory: AG Metrology S.r.l.\nMeasurement point and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type S\n0.11 – 0.0022 % rdg °C with 0° C RJ\n0.17 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Simulation use with Thermocouple Type S\n0.032 °C + 0.0012 % rdg with 0° C RJ\n0.14 °C with internal RJ\n(399\, 700\, 1000\, 1300\, 1700) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with Thermocouple Type T\n0.029 °C – 0.0033 % rdg with 0° C RJ\n0.13 °C – 0.0083 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Simulation use with Thermocouple Type T\n0.015 °C with 0° C RJ\n0.13 °C – 0.0067 % rdg with internal RJ\n(-200\, -100\, 100\, 250\, 399) °C\n\n\nTemperature Calibration\, Indication and Control Equipment used with RTD\n0.0020 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\nTemperature Simulation use with RTD\n0.0019 % rdg + 0.005 °C\n (-200\, 0\, 200\, 400\, 600\, 800) °C\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in June \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043e_05_ag/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Beamex-MC5.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270705
DTEND;VALUE=DATE:20270706
DTSTAMP:20261122T133101
CREATED:20260118T082742Z
LAST-MODIFIED:20261119T115224Z
UID:3807-1814745600-1814831999@www.agmetrology.com
SUMMARY:17043E_01_03_HVP_EX
DESCRIPTION:High voltage meter with probe calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: high voltage meter + probe\nModel: Vitrek 4700 + Vitrek HVL-70\nExternal provider for the calibration of the PT item:  an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nDCV RANGE\n\n\n\n\n1600.00 V\n0.01 % rdg\n1000.00 V\n\n\n16000.0 V\n0.01 % rdg\n(-10000.0\, 10000.0) V\n\n\n70000 V\n0.01 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\nACV RANGE 50 Hz\n\n\n\n\n1600.00 V\n0.05 % rdg\n1000.00 V\n\n\n 16000.0 V\n0.05 % rdg\n10000.0 V\n\n\n70000 V\n0.05 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: even-numbered years in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_hvp_ex/
CATEGORIES:ILC - Electrical
END:VEVENT
END:VCALENDAR