BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T215545
CREATED:20211205T165512Z
LAST-MODIFIED:20260729T093640Z
UID:605-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCL_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nEPTIS ID: 882510\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp with display for low currents AC / DC\nModel: UNI-T UT211B\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI\nMeasurement points: \nDCI \nRange 6000 mA ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nACI \nRange 600.0 mA 50 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 100 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 400 Hz ⇒ (60.0\, 540.0) mA\n6000 mA 50 Hz ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nReference Laboratory CMC:\nRange 1 µA < I ≤ 1 A ⇒ da 2.5 x 10-5 x I a 1.4 x 10-5 x I\n1 A < I ≤ 10 A ⇒ da 1.4 x 10-5 x I a 1.7 x 10-5 x I \nRange 2.5 mA < I ≤ 3 A 40 Hz ≤ f ≤ 10 kHz ⇒ 1.3 X 10-4 X I\n50 mA < I ≤ 100 A 40 Hz ≤ f ≤ 60 Hz ⇒ 1.3 X 10-4 X I \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the ILC participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_ccl_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCL-1.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T215545
CREATED:20211205T171248Z
LAST-MODIFIED:20260421T074623Z
UID:609-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCT_EX
DESCRIPTION:Current clamp transducer AC  calibration \nEPTIS ID: 882534\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp transducer AC\nModel: Hioki CT9667-02\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\nRange 500 A (1mV AC / A) 50 Hz    ⇒     (50\, 450) A\nRange 5000 A (0.1 mV AC / A) 50 Hz     ⇒     (500\, 1500\, 2500\, 3500\, 4500) A \nReference Laboratory CMC: \n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤ f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n  100 A < I ≤ 240 A\n40 Hz ≤ f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n 240 A < I ≤ 10 kA\n40 Hz ≤ f ≤ 60 Hz\n1.0 x 10^-4 x I\n\n\n\n\nNote:Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cct_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCT-HIOKI.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20260920T215545
CREATED:20211205T173620Z
LAST-MODIFIED:20260421T074603Z
UID:614-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCH_EX
DESCRIPTION:Current clamp with display for high currents AC / DC \nEPTIS ID: 882516\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: Current clamp with display for high currents AC / DC\nModel: ASITA DURA PA610\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points: \n\n\nDCI \n\n\n\nRange\n60.00 A\n6.00 A\, 54.00 A\n\n\n\n\n\n600.00 A\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A\n100 A\, 900 A\n\n\n\n\n\n\nACI \n\n\n\nRange\n60.00 A 50 Hz\n6.00 A\, 54.00 A\n\n\n\n\n\n60.00 A 100 Hz\n6.00 A\n\n\n\n60.00 A 400 Hz\n6.00 A\n\n\n\n600.0 A 50 Hz\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A 50 Hz\n100 A\, 900 A\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nRange\n1 A < I ≤ 10 A\nda 1.4 x 10^-5 x I a 1.7 x 10^-5 x I\n\n\n\n\n\n10 A < I ≤ 100 A\nda 1.7 x 10^-5 x I a 4.8 x 10^-5 x I\n\n\n\n100 A < I ≤ 300 A\n1.2 x 10^-4 x I\n\n\n\n300 A < I ≤ 1750 A\n4.4 x 10^-4 x I\n\n\n\n\n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n3 A < I ≤ 20 A\n40 Hz ≤f ≤10 kHz\n2.0 x 10^-4 x I\n\n\n\n 100 A < I ≤ 240 A\n40 Hz ≤f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n240 A < I ≤ 1000 A\n40 Hz ≤f ≤ 60 Hz\n1.0 x 10^-3 x I\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment:bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cch_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCH.png