BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:AG Metrology
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20270328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20271031T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T135306
CREATED:20211205T165512Z
LAST-MODIFIED:20261001T093348Z
UID:605-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCL_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nEPTIS ID: 882510\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp with display for low currents AC / DC\nModel: UNI-T UT211B\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value\nMeasurement points: \nDCI \nRange 6000 mA ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nACI \nRange 600.0 mA 50 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 100 Hz ⇒ (60.0\, 540.0) mA\n600.0 mA 400 Hz ⇒ (60.0\, 540.0) mA\n6000 mA 50 Hz ⇒ (600\, 1800\, 3000\, 4200\, 5400) mA \nCMC from the calibration laboratory’s accreditation schedule:\nRange 1 µA < I ≤ 1 A ⇒ da 2.5 x 10-5 x I a 1.4 x 10-5 x I\n1 A < I ≤ 10 A ⇒ da 1.4 x 10-5 x I a 1.7 x 10-5 x I \nRange 2.5 mA < I ≤ 3 A 40 Hz ≤ f ≤ 10 kHz ⇒ 1.3 X 10-4 X I\n50 mA < I ≤ 100 A 40 Hz ≤ f ≤ 60 Hz ⇒ 1.3 X 10-4 X I \nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_ccl_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCL-1.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T135306
CREATED:20211205T171248Z
LAST-MODIFIED:20261001T093321Z
UID:609-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCT_EX
DESCRIPTION:Current clamp transducer AC  calibration \nEPTIS ID: 882534\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: current clamp transducer AC\nModel: Hioki CT9667-02\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points:\nRange 500 A (1mV AC / A) 50 Hz    ⇒     (50\, 450) A\nRange 5000 A (0.1 mV AC / A) 50 Hz     ⇒     (500\, 1500\, 2500\, 3500\, 4500) A \nCMC from the calibration laboratory’s accreditation schedule: \n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤ f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n  100 A < I ≤ 240 A\n40 Hz ≤ f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n 240 A < I ≤ 10 kA\n40 Hz ≤ f ≤ 60 Hz\n1.0 x 10^-4 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cct_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCT-HIOKI.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20270301
DTEND;VALUE=DATE:20270302
DTSTAMP:20261122T135306
CREATED:20211205T173620Z
LAST-MODIFIED:20261001T093257Z
UID:614-1803859200-1803945599@www.agmetrology.com
SUMMARY:17043E_01_03_CCH_EX
DESCRIPTION:Current clamp with display for high currents AC / DC \nEPTIS ID: 882516\nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: Current clamp with display for high currents AC / DC\nModel: ASITA DURA PA610\nExternal provider for the calibration of the PT item: an ISO/IEC 17025 accredited laboratory or NMI\, used by AG Metrology (PT provider) to determine the assigned value \nMeasurement points and CMC from the calibration laboratory’s accreditation schedule: \n\n\nDCI \n\n\n\nRange\n60.00 A\n6.00 A\, 54.00 A\n\n\n\n\n\n600.00 A\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A\n100 A\, 900 A\n\n\n\n\n\n\nACI \n\n\n\nRange\n60.00 A 50 Hz\n6.00 A\, 54.00 A\n\n\n\n\n\n60.00 A 100 Hz\n6.00 A\n\n\n\n60.00 A 400 Hz\n6.00 A\n\n\n\n600.0 A 50 Hz\n60.0 A\, 180.0 A\, 300.0 A\, 420.0 A\, 540.0 A\n\n\n\n1000 A 50 Hz\n100 A\, 900 A\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nRange\n1 A < I ≤ 10 A\nda 1.4 x 10^-5 x I a 1.7 x 10^-5 x I\n\n\n\n\n\n10 A < I ≤ 100 A\nda 1.7 x 10^-5 x I a 4.8 x 10^-5 x I\n\n\n\n100 A < I ≤ 300 A\n1.2 x 10^-4 x I\n\n\n\n300 A < I ≤ 1750 A\n4.4 x 10^-4 x I\n\n\n\n\n\n\n\n\n\nRange\n50 mA < I ≤ 100 A\n40 Hz ≤f ≤ 60 Hz\n1.3 x 10^-4 x I\n\n\n\n\n\n3 A < I ≤ 20 A\n40 Hz ≤f ≤10 kHz\n2.0 x 10^-4 x I\n\n\n\n 100 A < I ≤ 240 A\n40 Hz ≤f ≤ 60 Hz\n1.9 x 10^-4 x I\n\n\n\n240 A < I ≤ 1000 A\n40 Hz ≤f ≤ 60 Hz\n1.0 x 10^-3 x I\n\n\n\n\nThe uncertainty actually used depends on the istrument and a stability  contribution\, finalised each round. The laboratory only calibrates; AG Metrology alone determines the assigned value and is responsible for the PT scheme. \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in March \nPayment:bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_cch_ex/
CATEGORIES:ILC - Electrical
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/CCH.png
END:VEVENT
END:VCALENDAR