BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260909T125025
CREATED:20211210T182113Z
LAST-MODIFIED:20251102T155933Z
UID:680-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_04_EX
DESCRIPTION:Leakage current\, earth bond resistance meter \nEPTIS ID: 882600\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: PAT tester\nModel: Metrel MI2142 AlphaPAT\nReference laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\nDifferential leakage\n(2\, 5\, 10\, 15) mA\n0.3 % rdg + 2.0 µA\n\n\nTouch leakage\n(1.0\, 1.5) mA\n0.3 % rdg + 2.0 µA\n\n\n Earth bond resistance\n 500 mΩ\n 8.0 mΩ\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_04_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/AlphaPAT.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260909T125025
CREATED:20211210T180945Z
LAST-MODIFIED:20251102T155910Z
UID:678-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_03_EX
DESCRIPTION:DCV\, ACV dielectric strength test meter  \nEPTIS ID: 882638\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: AC/DC/IR Hipot tester\nModel: Quadtech Sentry 30 Plus\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nMeasurement points\n\nCMC\n\n\n\n\nDielectric strength DCV\n (1000\, 3000\, 5000) V\n0.30 % rdg + 5 V\n\n\nDielectric strength ACV 50 Hz\n (1000\, 3000\, 5000) V\n0.50 % rdg + 5 V\n\n\n\n\n\n\n\n\n\nMeasurement points\n\n\nCMC\n\n\n\n\nDielectric strength DCV\n1000 V\n2000 V\n5000 V\n1 mA\n4 mA\n1 mA\n0.20 % rdg\n\n\nDielectric strength ACV\n1000 V\n2000 V\n5000 V\n1 mA\n14 mA\n15 mA\n0.20 % rdg\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_03_ex/
CATEGORIES:ILC - Electrical safety
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260909T125025
CREATED:20211209T171746Z
LAST-MODIFIED:20251102T155852Z
UID:676-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_02_EX
DESCRIPTION:Fault loop impedance with high current meter \nEPTIS ID: 882556\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: Loop impedance meter\nModel / type: Thytronic Impmeter2\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n80 mΩ\n3.0 mΩ\n\n\n100 mΩ\n3.0 mΩ\n\n\n130 mΩ\n3.0 mΩ\n\n\n0.20 Ω\n15 mΩ\n\n\n 0.90 Ω\n19 mΩ\n\n\n5.0 Ω\n44 mΩ\n\n\n9.0 Ω\n68 mΩ\n\n\n19 Ω\n0.13 Ω\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_02_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/Thytronic-Impmeter2.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260909T125025
CREATED:20211209T162423Z
LAST-MODIFIED:20251102T155830Z
UID:671-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_01_EX
DESCRIPTION:Impedance\, differential time and tripping current test\, earth resistance meter calibration \nEPTIS ID: 882562\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: multifunctional measuring instrument\nModel / type: Metrel MI 3100 SE\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nImpedance measurement \n1. Z LINE: line impedance phase-neutral / phase (METREL MI 3100 s)\n2. Z LOOP: impedance of the fault loop phase / earth (METREL MI 3100 s)\n3. Zs rcd: impedance of the fault loop with low test current (METREL MI 3100 s) \nMeasurement points: \n\n\n\n\n\n UUT setting\nNominal measurement points\n\n\n\n\nZ line\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZ loop\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZs rcd\n(0.50\, 1.80\, 5.00) Ω\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.50 Ω\n8 mΩ\n\n\n1.80 Ω\n18 mΩ\n\n\n5.00 Ω\n30 mΩ\n\n\n50.0 Ω\n0.39 Ω\n\n\n100.0 Ω\n0.50 Ω\n\n\n180 Ω\n1.0 Ω\n\n\n\n\nDifferential tripping time (RCD t) and current (RCD I) \nMeasurement points:\nTrip Out time (RCD t) \n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA X1 – AC – 0°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n300 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n30 mA X1 – AC – 180°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- Selective\n390 ms\n\n\n30 mA X2 – AC – 0°- general non delayed\n150 ms\n\n\n30 mA X5 – AC – 0°- general non delayed\n40 ms\n\n\n500 mA X5 – AC – 0°- general non delayed\n20 ms\n\n\n\nTrip Out current (RCD I)\nExecution of the points in the table to 20 ms (Trip out time reference) \n\n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA – AC – 0° – general non delayed\n10 mA\n\n\n30 mA – AC – 0° – general non delayed\n30 mA\n\n\n1000 mA – AC – 0° – general non delayed\n1000 mA\n\n\n30 mA – AC – 180° – general non delayed\n30 mA\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\nRCD trip Time\n0.020 % rdg + 0.25 ms\n\n\nRCD trip Current\n1.0 % rdg\n\n\n\n\nMeasurement of earth resistance value \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.10 Ω\n5.0 mΩ\n\n\n1.0 Ω\n10 mΩ\n\n\n10 Ω\n60 mΩ\n\n\n100 Ω\n0.50 Ω\n\n\n900 Ω\n5.0 Ω\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_01_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Metrel-MI3100-s.png
END:VEVENT