BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//AG Metrology - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:AG Metrology
X-ORIGINAL-URL:https://www.agmetrology.com
X-WR-CALDESC:Events for AG Metrology
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/Rome
BEGIN:DAYLIGHT
TZOFFSETFROM:+0100
TZOFFSETTO:+0200
TZNAME:CEST
DTSTART:20260329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0200
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20261025T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20260101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260706
DTEND;VALUE=DATE:20260707
DTSTAMP:20260624T210519
CREATED:20211129T143141Z
LAST-MODIFIED:20250810T085642Z
UID:543-1783296000-1783382399@www.agmetrology.com
SUMMARY:17043T_01_T_AG
DESCRIPTION:T type thermocouple calibration \nEPTIS ID: 797772\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: Thermocouple\nModel / type: T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-80 °C\n0.13 °C\n\n\n-60 °C\n0.13 °C\n\n\n-40 °C\n0.13 °C\n\n\n-20 °C\n0.13 °C\n\n\n0 °C\n0.13 °C\n\n\n50 °C\n0.13 °C\n\n\n100 °C\n0.14 °C\n\n\n150 °C\n0.14 °C\n\n\n200 °C\n0.14 °C\n\n\n250 °C\n0.14 °C\n\n\n300 °C\n0.14 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_01-eptis-id-797772/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/ILC-TC-S.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260706
DTEND;VALUE=DATE:20260707
DTSTAMP:20260624T210519
CREATED:20211207T102108Z
LAST-MODIFIED:20250731T162122Z
UID:633-1783296000-1783382399@www.agmetrology.com
SUMMARY:17043T_03_T_AG
DESCRIPTION:T type thermocouple with digital readout thermometer calibration \nEPTIS ID: 909671\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: digital readout with thermocouple\nModel / type: digital readout Eurotron MicroCal 1000 + T type thermocouple\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-80\, -60\, -40\, -20\, 0\, 50\, 100\, 150\, 200\, 250\, 300) °C \nReference laboratory CMC:\n0.12 °C \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_03_t-eptis-id-909671/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Catena-TC-T.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260706
DTEND;VALUE=DATE:20260707
DTSTAMP:20260624T210519
CREATED:20260118T082742Z
LAST-MODIFIED:20260313T164357Z
UID:3807-1783296000-1783382399@www.agmetrology.com
SUMMARY:17043E_01_03_HVP_EX
DESCRIPTION:Current clamp with display for low currents AC / DC calibration \nPT scheme / program name: Electrical calibration\nPT item type: AC/DC Voltage\, AC/DC Current\, Resistance\nSample / item: high voltage meter + probe\nModel: Vitrek 4700 + Vitrek HVL-70\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI\nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nType of Test\nCMC\nMeasurement Points\n\n\n\n\nDCV RANGE\n\n\n\n\n1600.00 V\n0.01 % rdg\n1000.00 V\n\n\n16000.0 V\n0.01 % rdg\n(-10000.0\, 10000.0) V\n\n\n70000 V\n0.01 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\nACV RANGE 50 Hz\n\n\n\n\n1600.00 V\n0.05 % rdg\n1000.00 V\n\n\n 16000.0 V\n0.05 % rdg\n10000.0 V\n\n\n70000 V\n0.05 % rdg\n (20000\, 30000\, 40000\, 50000\, 60000\, 70000) V\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for ILC: even-numbered years in July \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043e_01_03_hvp_ex/
CATEGORIES:ILC - Electrical
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20211209T162423Z
LAST-MODIFIED:20251102T155830Z
UID:671-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_01_EX
DESCRIPTION:Impedance\, differential time and tripping current test\, earth resistance meter calibration \nEPTIS ID: 882562\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: multifunctional measuring instrument\nModel / type: Metrel MI 3100 SE\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nImpedance measurement \n1. Z LINE: line impedance phase-neutral / phase (METREL MI 3100 s)\n2. Z LOOP: impedance of the fault loop phase / earth (METREL MI 3100 s)\n3. Zs rcd: impedance of the fault loop with low test current (METREL MI 3100 s) \nMeasurement points: \n\n\n\n\n\n UUT setting\nNominal measurement points\n\n\n\n\nZ line\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZ loop\n(0.50\, 1.80\, 5.00\, 50.0\, 100.0\, 180) Ω\n\n\nZs rcd\n(0.50\, 1.80\, 5.00) Ω\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.50 Ω\n8 mΩ\n\n\n1.80 Ω\n18 mΩ\n\n\n5.00 Ω\n30 mΩ\n\n\n50.0 Ω\n0.39 Ω\n\n\n100.0 Ω\n0.50 Ω\n\n\n180 Ω\n1.0 Ω\n\n\n\n\nDifferential tripping time (RCD t) and current (RCD I) \nMeasurement points:\nTrip Out time (RCD t) \n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA X1 – AC – 0°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n300 mA X1 – AC – 0°- general non delayed\n(150\, 300) ms\n\n\n30 mA X1 – AC – 180°- general non delayed\n300 ms\n\n\n30 mA X1 – AC – 0°- Selective\n390 ms\n\n\n30 mA X2 – AC – 0°- general non delayed\n150 ms\n\n\n30 mA X5 – AC – 0°- general non delayed\n40 ms\n\n\n500 mA X5 – AC – 0°- general non delayed\n20 ms\n\n\n\nTrip Out current (RCD I)\nExecution of the points in the table to 20 ms (Trip out time reference) \n\n\n\n\n\n\nUUT setting\nNominal measurement points\n\n\n\n\n10 mA – AC – 0° – general non delayed\n10 mA\n\n\n30 mA – AC – 0° – general non delayed\n30 mA\n\n\n1000 mA – AC – 0° – general non delayed\n1000 mA\n\n\n30 mA – AC – 180° – general non delayed\n30 mA\n\n\n\n\nReference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\nRCD trip Time\n0.020 % rdg + 0.25 ms\n\n\nRCD trip Current\n1.0 % rdg\n\n\n\n\nMeasurement of earth resistance value \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n0.10 Ω\n5.0 mΩ\n\n\n1.0 Ω\n10 mΩ\n\n\n10 Ω\n60 mΩ\n\n\n100 Ω\n0.50 Ω\n\n\n900 Ω\n5.0 Ω\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_01_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/Metrel-MI3100-s.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20211209T171746Z
LAST-MODIFIED:20251102T155852Z
UID:676-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_02_EX
DESCRIPTION:Fault loop impedance with high current meter \nEPTIS ID: 882556\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: Loop impedance meter\nModel / type: Thytronic Impmeter2\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nValue\nCMC\n\n\n\n\n80 mΩ\n3.0 mΩ\n\n\n100 mΩ\n3.0 mΩ\n\n\n130 mΩ\n3.0 mΩ\n\n\n0.20 Ω\n15 mΩ\n\n\n 0.90 Ω\n19 mΩ\n\n\n5.0 Ω\n44 mΩ\n\n\n9.0 Ω\n68 mΩ\n\n\n19 Ω\n0.13 Ω\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_02_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/Thytronic-Impmeter2.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20211210T180945Z
LAST-MODIFIED:20251102T155910Z
UID:678-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_03_EX
DESCRIPTION:DCV\, ACV dielectric strength test meter  \nEPTIS ID: 882638\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: AC/DC/IR Hipot tester\nModel: Quadtech Sentry 30 Plus\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nMeasurement points\n\nCMC\n\n\n\n\nDielectric strength DCV\n (1000\, 3000\, 5000) V\n0.30 % rdg + 5 V\n\n\nDielectric strength ACV 50 Hz\n (1000\, 3000\, 5000) V\n0.50 % rdg + 5 V\n\n\n\n\n\n\n\n\n\nMeasurement points\n\n\nCMC\n\n\n\n\nDielectric strength DCV\n1000 V\n2000 V\n5000 V\n1 mA\n4 mA\n1 mA\n0.20 % rdg\n\n\nDielectric strength ACV\n1000 V\n2000 V\n5000 V\n1 mA\n14 mA\n15 mA\n0.20 % rdg\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_03_ex/
CATEGORIES:ILC - Electrical safety
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20211210T182113Z
LAST-MODIFIED:20251102T155933Z
UID:680-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_04_EX
DESCRIPTION:Leakage current\, earth bond resistance meter \nEPTIS ID: 882600\nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: PAT tester\nModel: Metrel MI2142 AlphaPAT\nReference laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\nDifferential leakage\n(2\, 5\, 10\, 15) mA\n0.3 % rdg + 2.0 µA\n\n\nTouch leakage\n(1.0\, 1.5) mA\n0.3 % rdg + 2.0 µA\n\n\n Earth bond resistance\n 500 mΩ\n 8.0 mΩ\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043s_04_ex/
CATEGORIES:ILC - Electrical safety
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2021/12/AlphaPAT.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20241019T165231Z
LAST-MODIFIED:20251102T160028Z
UID:2455-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043T_06_AG
DESCRIPTION:Dew / frost point temperature meter calibration \nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nItem: dew / frost point meter\nModel: General Eastern Optica + General Eastern D2\nReference Laboratory: AG Metrology S.r.l. \nMeasurement points:\n(-25\, -15\, -5\, 5\, 15\, 25) °C \nReference Laboratory CMC:\n0.19 °C \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_06_ag/
CATEGORIES:ILC - Dew point
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20241117T165904Z
LAST-MODIFIED:20251102T155956Z
UID:2848-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043S_05_EX
DESCRIPTION:Insulation resistance meter \nPT scheme / program name: Electrical calibration\nPT item type: Electrical safety\nSample / item: insulation resistance meter\nModel / type: AEMC 5050\nReference laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points and Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\n\nCMC\n\n\n\n\n(0.1\, 0.5\, 1.0\, 5.0\, 10\, 100\, 190) MΩ\n50 V\n0.3 % rdg\n\n\n( 0.5\, 1.0\, 5.0\, 10\, 100\, 190) MΩ\n500 V\n0.3 % rdg\n\n\n(1\, 2\, 3\, 5\, 10\, 15\, 20\, 25\, 30) MΩ\n1000 V\n1.0 % rdg\n\n\n(1\, 10\, 100\, 1000) GΩ\n5000 V\n2.0 % rdg\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043s_05_ex/
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260907
DTEND;VALUE=DATE:20260908
DTSTAMP:20260624T210519
CREATED:20250703T172410Z
LAST-MODIFIED:20251102T155759Z
UID:3213-1788739200-1788825599@www.agmetrology.com
SUMMARY:17043T_05_HT_EX
DESCRIPTION:Infrared thermometer calibration \nEPTIS ID: 1394698\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: infrared thermometer\nModel / type: Minolta Land Cyclops 152\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points and CMC of Reference Laboratory: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n600 °C\n0.90 °C\n\n\n800 °C\n0.90 °C\n\n\n1000 °C\n1.0 °C\n\n\n1200 °C\n1.0 °C\n\n\n1400 °C\n 1.5 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in PT participation protocol \nScheduled start date for PT: every year in September \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043t_05_ht_ex-eptis-id-1394698/
CATEGORIES:ILC - Temperature
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20211129T115504Z
LAST-MODIFIED:20251214T095752Z
UID:528-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_-95_100_kR_AG
DESCRIPTION:Pneumatic pressure transducer from -95 kPa to 100 kPa calibration\, gauge pressure \nEPTIS ID: 806743\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: GE Druck DPI150\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-95\, -80\, -60\, -40\, -20\, 0\, 20\, 40\, 60\, 80\, 100) kPa \nReference Laboratory CMC:\n|0.0028 %| rdg + 0.28 Pa (range -95 kPa to atm)\n0.0023 % rdg + 0.21 Pa (range atm kPa to 100 kPa) \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_-95kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/Gemini_Generated_Image_rmst6qrmst6qrmst.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20211129T143255Z
LAST-MODIFIED:20251214T095843Z
UID:545-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_7MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 7 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.0\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0023 % rdg + 0.26 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20211210T182810Z
LAST-MODIFIED:20260421T074125Z
UID:667-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043T_02_EX
DESCRIPTION:SPRT calibration \nEPTIS ID: 848623\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / item: 4 wires resistance thermometer\nModel / type: Rosemount 162CE\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points e Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.005 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/ilc-17043t_02-eptis-id-848623/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/SPRT.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20231228T160035Z
LAST-MODIFIED:20260421T074104Z
UID:2126-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043T_03_PT_EX
DESCRIPTION:SPRT with Digital Readout Thermometer calibration  \nEPTIS ID: 708020\nPT scheme / program name: Thermodynamic calibration\nPT item type: Temperature\nSample / Item: SPRT with a Digital Readout Thermometer calibration\nModel / type: Fluke 1522 + Fluke 5609-400-G\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement points e Reference Laboratory CMC: \n\n\n\n\n\nMeasurement Points\nCMC\n\n\n\n\n-196 °C\n0.020 °C\n\n\n-80 °C\n0.005 °C\n\n\n-40 °C\n0.004 °C\n\n\n0 °C\n0.004 °C\n\n\n100 °C\n0.004 °C\n\n\n250 °C\n0.004 °C\n\n\n420 °C\n0.012 °C\n\n\n600 °C\n0.012 °C\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer
URL:https://www.agmetrology.com/event/17043t_03_pt_ex-eptis-id-708020/
CATEGORIES:ILC - Temperature
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2023/12/catena-e1703780406498.jpeg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241027T101946Z
LAST-MODIFIED:20260421T074537Z
UID:2556-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_-25kR_AG
DESCRIPTION:Pneumatic pressure transducer from -25 kPa to atm calibration\, negative gauge pressure \nEPTIS ID: 806743\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: Mensor CPG2500\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(-25.0\, -22.5\, -20.0\, -17.5\, -15.0\, -12.5\, -10.0\, -7.5\, -5.0\, -2.5\, 0.0) kPa \nReference Laboratory CMC:\n|0.0028 %| rdg + 0.28 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_-25kr_ag/
CATEGORIES:ILC - Pressure
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T083030Z
LAST-MODIFIED:20251214T095623Z
UID:2586-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_-25_25kR_AG
DESCRIPTION:Pneumatic pressure transducer from -25 kPa to 25 kPa calibration\, gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0004\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.0\, 2.5\, 5.0\, 7.5\, 10.0\, 12.5\, 15.0\, 17.5\, 20.0\, 22.5\, 25.0) kPa \nReference Laboratory CMC:\n|0.0028 %| rdg + 0.28 Pa (range -25 kPa to atm)\n0.0023 % rdg + 0.21 Pa (range atm kPa to 25 kPa) \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_25kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0004.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T084057Z
LAST-MODIFIED:20251214T100713Z
UID:2589-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_170kA_AG
DESCRIPTION:Pneumatic pressure transducer from 1.4 kPa to 170 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: Paroscientific 735 + Paroscientific DigiQuartz 230A-180\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(1.4\, 17.0\, 34.0\, 51.0\, 68.0\, 85.0\, 102.0\, 119.0\, 136.0\, 153.0\, 170.0) kPa \nReference Laboratory CMC:\n0.0020 % rdg + 0.48 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_170ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T092403Z
LAST-MODIFIED:20260421T074516Z
UID:2597-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_350kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 350 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DHI RPM1-G0100-R\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 35\, 70\, 105\, 140\, 175\, 210\, 245\, 280\, 315\, 350) kPa \nReference Laboratory CMC:\n0.0023 % rdg + 0.26 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_350kr_ag/
CATEGORIES:ILC - Pressure
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T092926Z
LAST-MODIFIED:20251214T095806Z
UID:2601-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_700kR_AG
DESCRIPTION:Pneumatic pressure transducer up to 700 kPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 G0100\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0023 % rdg + 0.26 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700kr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-G0100.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T093904Z
LAST-MODIFIED:20251214T102608Z
UID:2603-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_700kA_AG
DESCRIPTION:Pneumatic pressure transducer from 12 kPa to 700 kPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: ‘Paroscientific Digiquartz 715 + Paroscientific Digiquartz 6000-100A\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(12\, 70\, 140\, 210\, 280\, 350\, 420\, 490\, 560\, 630\, 700) kPa \nReference Laboratory CMC:\n0.0025 % rdg + 0.48 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_700ka_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-715-6000-100A.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T094759Z
LAST-MODIFIED:20251214T091617Z
UID:2606-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_3.5MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 3.5 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: CalRef Cube-P\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0023 % rdg + 0.26 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Cube-P.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210519
CREATED:20241102T095222Z
LAST-MODIFIED:20251214T103727Z
UID:2608-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_3.5MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.17 MPa to 3.5 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nItem: pressure transducer\nModel: DH Instruments RPM1 A0500\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.17\, 0.35\, 0.70\, 1.05\, 1.40\, 1.75\, 2.10\, 2.45\, 2.80\, 3.15\, 3.50) MPa \nReference Laboratory CMC:\n0.0025 % rdg + 0.48 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_3-5ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/RPM1-A0500.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210520
CREATED:20241102T095819Z
LAST-MODIFIED:20251214T103755Z
UID:2611-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_7MA_AG
DESCRIPTION:Pneumatic pressure transducer from 0.2 MPa to 7 MPa calibration\, absolute pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: RPM3 A10000/A1000\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0.2\, 0.7\, 1.4\, 2.1\, 2.8\, 3.5\, 4.2\, 4.9\, 5.6\, 6.3\, 7.0) MPa \nReference Laboratory CMC:\n0.0025 % rdg + 0.48 Pa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_7ma_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/11/RPM3-A10000-A1000.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261005
DTEND;VALUE=DATE:20261006
DTSTAMP:20260624T210520
CREATED:20241102T100749Z
LAST-MODIFIED:20260520T141034Z
UID:2617-1791158400-1791244799@www.agmetrology.com
SUMMARY:17043P_03_20MR_AG
DESCRIPTION:Pneumatic pressure transducer up to 20 MPa calibration\, positive gauge pressure \nEPTIS ID: 711307\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific 745-3K\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 2\, 4\, 6\, 8\, 10\, 12\, 14\, 16\, 18\, 20) MPa \nReference Laboratory CMC: \n0.005 5 % rdg + 1.8 kPa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in October \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_20mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-sn-1192-230A-180.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260624T210520
CREATED:20211204T172346Z
LAST-MODIFIED:20251214T104748Z
UID:572-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_35MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 35 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM4 A200Ms-L/A70Ms\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 3.5\, 7.0\, 10.5\, 14.0\, 17.5\, 21.0\, 24.5\, 28.0\, 31.5\, 35.0) MPa \nReference Laboratory Measurement:\n0.0054 % rdg + 0.24 kPa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_35mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260624T210520
CREATED:20241102T102317Z
LAST-MODIFIED:20260520T122311Z
UID:2624-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_100MR_AG
DESCRIPTION:Hydraulic pressure transducer up to 100 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: Paroscientific DigiQuartz 735 + Paroscientific DigiQuartz 415K-101\nReference Laboratory: AG Metrology S.r.l. \nMeasurement Points:\n(0\, 10\, 20\, 30\, 40\, 50\, 60\, 70\, 80\, 90\, 100) MPa \nReference Laboratory Measurement:\n0.0055 % rdg + 2.2 Pa (up to 6 MPa)\n0.0076 % rdg + 2.0 Pa (range 6 MPa to 120 MPa) \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_100mr_ag/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2024/11/Paros-735-415K-101.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261109
DTEND;VALUE=DATE:20261110
DTSTAMP:20260624T210520
CREATED:20241102T103452Z
LAST-MODIFIED:20260520T141210Z
UID:2629-1794182400-1794268799@www.agmetrology.com
SUMMARY:17043P_03_280MR_EX
DESCRIPTION:Hydraulic pressure transducer up to 280 MPa calibration\, positive gauge pressure \nEPTIS ID: 773591\nPT scheme / program name: Mechanical calibration\nPT item type: Pressure\nSample / item: pressure transducer\nModel / type: DH Instruments RPM4 A280Ms-L\nReference Laboratory: NMI or Accreditated Laboratory according to ISO IEC 17025 in MRA field \nMeasurement Points:\n(0\, 28\, 56\, 84\, 112\, 140\, 168\, 196\, 224\, 252\, 280) MPa \nReference Laboratory CMC:\n0.0051 % rdg + 2.7 kPa \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in November \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043p_03_280mr_ex/
CATEGORIES:ILC - Pressure
ATTACH;FMTTYPE=image/png:https://www.agmetrology.com/wp-content/uploads/2021/12/RPM4-RPM4-A200Ms-L-A70Ms.png
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260624T210520
CREATED:20220522T155757Z
LAST-MODIFIED:20260421T074456Z
UID:1035-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043M_01_EX
DESCRIPTION:Set of weights class E2 from 1 mg to 10 kg  \nEPTIS ID: 935474\nPT scheme / program name: Mass calibration\nPT item type: Mass\nSample / item: weights\nModel: class E2\, from 1 mg to 10 kg\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n1 mg\, 10 mg\, 100 mg\, 1 g\, 10 g\, 100 g\, 1 kg\, 2 kg\, 5 kg\, 10 kg\nReference Laboratory CMC: \n\n\n\n\n\nMass\nCMC\n\n\n\n\n1 mg\n0.001 mg\n\n\n10 mg\n0.001 mg\n\n\n100 mg\n0.0016 mg\n\n\n1 g\n0.003 mg\n\n\n10 g\n0.006 mg\n\n\n100 g\n0.016 mg\n\n\n1 kg\n0.15 mg\n\n\n2 kg\n0.3 mg\n\n\n5 kg\n0.8 mg\n\n\n10 kg\n1.5 mg\n\n\n\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043m_01_ex/
CATEGORIES:ILC - Mass
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_masse.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260624T210520
CREATED:20220522T161041Z
LAST-MODIFIED:20260421T074425Z
UID:1038-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043AV_02_EX
DESCRIPTION:Air velocity meter from 2.0 m/s to 30 m/s \nEPTIS ID: 935490\nPT scheme / program name: Mechanical calibration\nPT item type: Air flow\nSample / item: anemometer\nModel / type: TSI Velocical 9535\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points:\n(2.0\, 5.0\, 7.0\, 15\, 23\, 30) m/s\nReference Laboratory CMC:\n0.47 % rdg + 0.004 m/s \nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every odd year in December \nPayment: by bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043av_02_ex/
CATEGORIES:ILC - Air Velocity
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/2_anemometro.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20261207
DTEND;VALUE=DATE:20261208
DTSTAMP:20260624T210520
CREATED:20220525T100535Z
LAST-MODIFIED:20260421T074716Z
UID:1057-1796601600-1796687999@www.agmetrology.com
SUMMARY:17043A_01_EX
DESCRIPTION:Sound Level Meter  \nEPTIS ID: 941623\nPT scheme / program name: Acoustic calibration\nPT item type: Sound Level Meter\nSample / item: acoustical measuring equipment\nModel: Bruel & Kjaer 2238 Mediator\nReference Laboratory: ISO IEC 17025 accreditated laboratory or NMI \nMeasurement Points: \n\nSelf generated noise\, range (0 – 80) dB\, Mode Leq\nAcoustical signal tests of frequency weighting\, range (50 – 130) dB\, Frequency Weighting setting C\, Time Weighting response Slow\nElectrical signal tests of frequency weightings\, range (50 – 130) dB\nFrequency and time weightings at 1 kHz\, range (50 – 130) dB\nLevel linearity on the reference level range\, range (50 – 130) dB\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nLevel linearity including the level range control\, Input Frequency 1 kHz SLM\, Measuring Mode SPL\nToneburst response\, range (50 – 130) dB\nC-weighted peak sound level\, range: (60 – 140) dB\nOverload indication\, Range: (60 – 140) dB\, SLM Measuring Mode LAEq\n\nReference Laboratory CMC: \n\nSound calibrators \, Sound pressure level : 84 dB (reference: 20 µPa)\nSound calibrator\, single frequency 1 kHz 0.26 dB\nSound calibrators \, Sound pressure level : 124 dB (reference: 20 µPa)\nPistonphone\, single frequency 250 Hz 0.12 dB\nSound measuring instruments \, Sound pressure response level : 94 dB (reference: 20 µPa) Sound level meter 0.30 dB\nSound calibrators \, Sound pressure level : 94 dB (reference: 20 µPa) to 114 dB (reference: 20 µPa) Sound calibrator\, single frequency 1 kHz 0.13 dB\n\nNote: Indications regarding organizational methods\, presentation and sending of results will be reported in the PT participation protocol \nScheduled start date for PT: every year in December \nPayment: bank transfer \nFor further information \nCONTACT US×Further information about the Proficiency Testing event\nFill in the fields and click on SEND to receive further information about the Proficiency Testing event you are interested in. \n\n\n  \n\n\n\n  Name  (required)\n  \n  Email  (required)\n  \n  Notes or requests \n  \nTerms and conditions  (required)\nI have read the  privacy policy  and I consent to the storage of my data in your archive according to what established by the European regulation for the protection of personal data n. 679/2016\, GDPR. (You can cancel them or request a copy by making an explicit request to info@agmetrology.com)\n\n ×
URL:https://www.agmetrology.com/event/17043a_01_ex/
CATEGORIES:ILC - Acoustic
ATTACH;FMTTYPE=image/jpeg:https://www.agmetrology.com/wp-content/uploads/2022/05/1_fonometro.jpg
END:VEVENT
END:VCALENDAR